Opened 5 months ago
Last modified 5 months ago
#1858 new enhancement
INTENSO SSD 128g not in the smartctl database
Reported by: | vipiet | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | unscheduled |
Component: | drivedb | Version: | |
Keywords: | ssd | Cc: |
Description
Hi Guys,
my SSD is not in the smartctl database 7.3/5610, could you add it?
Thanks and best,
Patrick
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.8.4-2-pve] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: INTENSO SSD Serial Number: 1642312006001303 Firmware Version: W0714A0 User Capacity: 128,035,676,160 bytes [128 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available Device is: Not in smartctl database 7.3/5610 ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Thu Aug 1 11:00:00 2024 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 120) seconds. Offline data collection capabilities: (0x11) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 10) minutes. SCT capabilities: (0x0001) SCT Status supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate -O--CK 100 100 050 - 0 5 Reallocated_Sector_Ct -O--CK 100 100 050 - 1 9 Power_On_Hours -O--CK 100 100 050 - 1547 12 Power_Cycle_Count -O--CK 100 100 050 - 23 160 Unknown_Attribute -O--CK 100 100 050 - 0 161 Unknown_Attribute PO--CK 100 100 050 - 94 163 Unknown_Attribute -O--CK 100 100 050 - 6 164 Unknown_Attribute -O--CK 100 100 050 - 5053 165 Unknown_Attribute -O--CK 100 100 050 - 82 166 Unknown_Attribute -O--CK 100 100 050 - 2 167 Unknown_Attribute -O--CK 100 100 050 - 20 168 Unknown_Attribute -O--CK 100 100 050 - 5050 169 Unknown_Attribute -O--CK 100 100 050 - 100 175 Program_Fail_Count_Chip -O--CK 100 100 050 - 0 176 Erase_Fail_Count_Chip -O--CK 100 100 050 - 0 177 Wear_Leveling_Count -O--CK 100 100 050 - 0 178 Used_Rsvd_Blk_Cnt_Chip -O--CK 100 100 050 - 1 181 Program_Fail_Cnt_Total -O--CK 100 100 050 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 050 - 0 192 Power-Off_Retract_Count -O--CK 100 100 050 - 14 194 Temperature_Celsius -O---K 100 100 050 - 40 195 Hardware_ECC_Recovered -O--CK 100 100 050 - 0 196 Reallocated_Event_Count -O--CK 100 100 050 - 0 197 Current_Pending_Sector -O--CK 100 100 050 - 1 198 Offline_Uncorrectable -O--CK 100 100 050 - 0 199 UDMA_CRC_Error_Count -O--CK 100 100 050 - 0 232 Available_Reservd_Space -O--CK 100 100 050 - 94 241 Total_LBAs_Written ----CK 100 100 050 - 13616 242 Total_LBAs_Read ----CK 100 100 050 - 22095 245 Unknown_Attribute -O--CK 100 100 050 - 29419 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x24 GPL R/O 88 Current Device Internal Status Data log 0x25 GPL R/O 32 Saved Device Internal Status Data log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 1547 - # 2 Extended offline Completed without error 00% 1547 - # 3 Extended offline Completed without error 00% 1405 - Selective Self-tests/Logging not supported SCT Status Version: 3 SCT Version (vendor specific): 0 (0x0000) Device State: Active (0) Current Temperature: 40 Celsius Power Cycle Min/Max Temperature: 40/40 Celsius Lifetime Min/Max Temperature: 22/40 Celsius Specified Max Operating Temperature: 100 Celsius Under/Over Temperature Limit Count: 0/0 SCT Data Table command not supported SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 23 --- Lifetime Power-On Resets 0x01 0x010 4 1547 --- Power-on Hours 0x01 0x018 6 892360040 --- Logical Sectors Written 0x01 0x020 6 20563297 --- Number of Write Commands 0x01 0x028 6 1448028657 --- Logical Sectors Read 0x01 0x030 6 14096700 --- Number of Read Commands 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 0 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
Change History (1)
comment:1 by , 5 months ago
Component: | all → drivedb |
---|---|
Keywords: | ssd added |
Milestone: | → unscheduled |
Type: | defect → enhancement |
Note:
See TracTickets
for help on using tickets.
Could be added to existing entry
Silicon Motion based OEM SSDs
.