Opened 6 months ago
Last modified 2 months ago
#1841 accepted enhancement
Add RTL9201R based Orico enclosure to DB (0x0bda:0x9201)
Reported by: | Adam | Owned by: | Christian Franke |
---|---|---|---|
Priority: | minor | Milestone: | Release 7.5 |
Component: | drivedb | Version: | 7.3 |
Keywords: | ssd usb | Cc: | Adam |
Description
Hi,
I'm using Orico 9606C3 enclosure to for M.2 Sata devices. Without any options the smartctl throws an error:
root@nas:/srv# smartctl -a /dev/sde smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.0-18-amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org /dev/sde: Unknown USB bridge [0x0bda:0x9201 (0xf200)] Please specify device type with the -d option. Use smartctl -h to get a usage summary
However with -d sat
option everything works way better.
root@nas:/srv# smartctl -d sat -a /dev/sde smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.0-18-amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SPCC M.2 SSD Serial Number: AA2022021280002432 Firmware Version: U1209A0 User Capacity: 128,035,676,160 bytes [128 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available Device is: Not in smartctl database 7.3/5610 ATA Version is: ACS-3 T13/2161-D revision 4 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 1.5 Gb/s) Local Time is: Sun Jun 16 22:36:51 2024 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART Status not supported: Incomplete response, ATA output registers missing SMART overall-health self-assessment test result: PASSED Warning: This result is based on an Attribute check. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 120) seconds. Offline data collection capabilities: (0x11) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 10) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0032 100 100 050 Old_age Always - 0 5 Reallocated_Sector_Ct 0x0032 100 100 050 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 050 Old_age Always - 425 12 Power_Cycle_Count 0x0032 100 100 050 Old_age Always - 64 160 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 0 161 Unknown_Attribute 0x0033 100 100 050 Pre-fail Always - 100 163 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 9 164 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 152 165 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 2 166 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 1 167 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 1 168 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 5050 169 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 100 175 Program_Fail_Count_Chip 0x0032 100 100 050 Old_age Always - 0 176 Erase_Fail_Count_Chip 0x0032 100 100 050 Old_age Always - 0 177 Wear_Leveling_Count 0x0032 100 100 050 Old_age Always - 0 178 Used_Rsvd_Blk_Cnt_Chip 0x0032 100 100 050 Old_age Always - 0 181 Program_Fail_Cnt_Total 0x0032 100 100 050 Old_age Always - 0 182 Erase_Fail_Count_Total 0x0032 100 100 050 Old_age Always - 0 192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age Always - 48 194 Temperature_Celsius 0x0022 100 100 050 Old_age Always - 40 195 Hardware_ECC_Recovered 0x0032 100 100 050 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 100 100 050 Old_age Always - 0 197 Current_Pending_Sector 0x0032 100 100 050 Old_age Always - 0 198 Offline_Uncorrectable 0x0032 100 100 050 Old_age Always - 0 199 UDMA_CRC_Error_Count 0x0032 100 100 050 Old_age Always - 0 232 Available_Reservd_Space 0x0032 100 100 050 Old_age Always - 100 241 Total_LBAs_Written 0x0030 100 100 050 Old_age Offline - 2418 242 Total_LBAs_Read 0x0030 100 100 050 Old_age Offline - 621 245 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 683 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 8 - # 2 Extended offline Completed without error 00% 7 - # 3 Extended offline Aborted by host 10% 7 - # 4 Extended offline Aborted by host 80% 7 - # 5 Short offline Completed without error 00% 0 - # 6 Short offline Aborted by host 80% 0 - Selective Self-tests/Logging not supported
Change History (4)
comment:1 by , 6 months ago
Component: | smartctl → drivedb |
---|---|
Keywords: | ssd usb added; Smart DB removed |
Milestone: | → unscheduled |
Summary: | Add RTL9201R based Orico enclosure to DB → Add RTL9201R based Orico enclosure to DB (0x0bda:0x9201) |
comment:3 by , 2 months ago
Owner: | set to |
---|---|
Status: | new → accepted |
comment:4 by , 2 months ago
Milestone: | unscheduled → Release 7.5 |
---|
Note:
See TracTickets
for help on using tickets.
I confirm with latest smartmontools and same RTL9201 chip (but not orico branded), I get the same error. Adding
-d sat
fixed it.It seems this chipset is a Realtek USB3.0 to SATA3 bridge.
lsusb
info of the realtek rtl9201 usb device: