Opened 6 years ago

Last modified 3 years ago

#1112 closed enhancement

Add Sandisk SD9SB8W128G1122 reference in the drivedb — at Version 1

Reported by: jeremy385892a Owned by:
Priority: minor Milestone: Release 7.3
Component: drivedb Version: 6.6
Keywords: ssd Cc:

Description (last modified by Christian Franke)

Could you add the following disk reference in the smartctl database ?

Here is the smartctl -a output:

>smartctl -a /dev/ada0
smartctl 6.3 2014-07-26 r3976 [NS-BSD 2.7.2- amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     SanDisk SD9SB8W128G1122
Serial Number:    174970801128
LU WWN Device Id: 5 001b44 8b688bbc1
Firmware Version: X6104000
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   Unknown(0x0ff0) (unknown minor revision code: 0x005e)
SATA Version is:  SATA >3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Fri Oct 19 08:23:03 2018 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x11) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  10) minutes.

SMART Attributes Data Structure revision number: 4
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0032   100   100   ---    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   100   100   ---    Old_age   Always       -       362
 12 Power_Cycle_Count       0x0032   100   100   ---    Old_age   Always       -       7
165 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       65536
166 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
167 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       23
168 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
169 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       78
170 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
171 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
173 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
174 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       4
184 End-to-End_Error        0x0032   100   100   ---    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   ---    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   ---    Old_age   Always       -       0
194 Temperature_Celsius     0x0022   072   041   ---    Old_age   Always       -       28 (Min/Max 25/41)
199 UDMA_CRC_Error_Count    0x0032   100   100   ---    Old_age   Always       -       0
230 Unknown_SSD_Attribute   0x0032   100   100   ---    Old_age   Always       -       0
232 Available_Reservd_Space 0x0033   100   100   004    Pre-fail  Always       -       100
233 Media_Wearout_Indicator 0x0032   100   100   ---    Old_age   Always       -       0
234 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       1
241 Total_LBAs_Written      0x0030   253   253   ---    Old_age   Offline      -       1
242 Total_LBAs_Read         0x0030   253   253   ---    Old_age   Offline      -       0
244 Unknown_Attribute       0x0032   000   100   ---    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported

Many thanks

Change History (1)

comment:1 by Christian Franke, 6 years ago

Description: modified (diff)
Note: See TracTickets for help on using tickets.