add to drivedb: Sandisk SD9SB8W (128G1122 / 512G-1006 / 256G-1122 / 1T-1122)
Could you add the following disk reference in the smartctl database ?
Here is the smartctl -a output:
>smartctl -a /dev/ada0
smartctl 6.3 2014-07-26 r3976 [NS-BSD 2.7.2- amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SanDisk SD9SB8W128G1122
Serial Number: 174970801128
LU WWN Device Id: 5 001b44 8b688bbc1
Firmware Version: X6104000
User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: Unknown(0x0ff0) (unknown minor revision code: 0x005e)
SATA Version is: SATA >3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Oct 19 08:23:03 2018 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SMART Attributes Data Structure revision number: 4
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
5 Reallocated_Sector_Ct 0x0032 100 100 --- Old_age Always - 0
9 Power_On_Hours 0x0032 100 100 --- Old_age Always - 362
12 Power_Cycle_Count 0x0032 100 100 --- Old_age Always - 7
165 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 65536
166 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0
167 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 23
168 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0
169 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 78
170 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0
171 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0
172 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0
173 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0
174 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 4
184 End-to-End_Error 0x0032 100 100 --- Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 --- Old_age Always - 0
188 Command_Timeout 0x0032 100 100 --- Old_age Always - 0
194 Temperature_Celsius 0x0022 072 041 --- Old_age Always - 28 (Min/Max 25/41)
199 UDMA_CRC_Error_Count 0x0032 100 100 --- Old_age Always - 0
230 Unknown_SSD_Attribute 0x0032 100 100 --- Old_age Always - 0
232 Available_Reservd_Space 0x0033 100 100 004 Pre-fail Always - 100
233 Media_Wearout_Indicator 0x0032 100 100 --- Old_age Always - 0
234 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 1
241 Total_LBAs_Written 0x0030 253 253 --- Old_age Offline - 1
242 Total_LBAs_Read 0x0030 253 253 --- Old_age Offline - 0
244 Unknown_Attribute 0x0032 000 100 --- Old_age Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Selective Self-tests/Logging not supported
Many thanks
Ulrich Windl reported a similar drive via database mailing list: