#1111 closed enhancement (duplicate)
Western Digital WD80EZAZ not in database
Reported by: | Craig Rounds | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | Release 7.0 |
Component: | drivedb | Version: | 6.6 |
Keywords: | Cc: |
Description (last modified by )
Attached is the smartctl-VENDOR-MODEL.txt Unknown Attribute 22 is "Helium level."
Thank you,
craigr
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.18.14-unRAID] (local build) Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD80EZAZ-11TDBA0 Serial Number: 7SJ3R0NW LU WWN Device Id: 5 000cca 252dddec9 Firmware Version: 83.H0A83 User Capacity: 8,001,563,222,016 bytes [8.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 3.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Thu Oct 18 18:00:41 2018 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 93) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: (1213) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0 2 Throughput_Performance --S--- 128 128 054 - 116 3 Spin_Up_Time POS--- 162 162 024 - 453 (Average 361) 4 Start_Stop_Count -O--C- 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate -O-R-- 100 100 067 - 0 8 Seek_Time_Performance --S--- 128 128 020 - 18 9 Power_On_Hours -O--C- 100 100 000 - 118 10 Spin_Retry_Count -O--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 9 22 Unknown_Attribute PO---K 100 100 025 - 100 192 Power-Off_Retract_Count -O--CK 100 100 000 - 37 193 Load_Cycle_Count -O--C- 100 100 000 - 37 194 Temperature_Celsius -O---- 250 250 000 - 26 (Min/Max 20/29) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL R/O 256 Device Statistics log 0x04 SL R/O 255 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x08 GPL R/O 2 Power Conditions log 0x09 SL R/W 1 Selective self-test log 0x0c GPL R/O 5501 Pending Defects log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x12 GPL R/O 1 SATA NCQ Non-Data log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x15 GPL R/W 1 Rebuild Assist log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x24 GPL R/O 256 Current Device Internal Status Data log 0x25 GPL R/O 256 Saved Device Internal Status Data log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 118 - # 2 Short offline Completed without error 00% 111 - # 3 Extended offline Completed without error 00% 105 - # 4 Short offline Completed without error 00% 86 - # 5 Short offline Completed without error 00% 20 - # 6 Extended offline Completed without error 00% 19 - # 7 Short offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 0 Device State: Active (0) Current Temperature: 26 Celsius Power Cycle Min/Max Temperature: 21/29 Celsius Lifetime Min/Max Temperature: 20/29 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/65 Celsius Min/Max Temperature Limit: -40/70 Celsius Temperature History Size (Index): 128 (1) Index Estimated Time Temperature Celsius 2 2018-10-18 15:53 22 *** ... ..(113 skipped). .. *** 116 2018-10-18 17:47 22 *** 117 2018-10-18 17:48 23 **** 118 2018-10-18 17:49 23 **** 119 2018-10-18 17:50 24 ***** 120 2018-10-18 17:51 24 ***** 121 2018-10-18 17:52 24 ***** 122 2018-10-18 17:53 25 ****** ... ..( 3 skipped). .. ****** 126 2018-10-18 17:57 25 ****** 127 2018-10-18 17:58 26 ******* 0 2018-10-18 17:59 26 ******* 1 2018-10-18 18:00 22 *** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) supported [please try: '-l defects'] SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS
Attachments (1)
Change History (6)
by , 6 years ago
Attachment: | smartctl-VENDOR-MODEL.txt added |
---|
comment:1 by , 6 years ago
Component: | all → drivedb |
---|---|
Description: | modified (diff) |
Type: | defect → enhancement |
smartctl-VENDOR-MODEL
For future submissions, please replace VENDOR-MODEL with vendor and model :-)
For example: smartctl-WDC-WD80EZAZ-11TDBA0.txt
.
comment:2 by , 6 years ago
Milestone: | → Release 6.7 |
---|---|
Resolution: | → duplicate |
Status: | new → closed |
See ticket #959.
Note:
See TracTickets
for help on using tickets.
smartctl-VENDOR-MODEL