Opened 6 years ago
Last modified 6 years ago
#1111 closed enhancement
Western Digital WD80EZAZ not in database — at Initial Version
Reported by: | Craig Rounds | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | Release 7.0 |
Component: | drivedb | Version: | 6.6 |
Keywords: | Cc: |
Description
Attached is the smartctl-VENDOR-MODEL.txt Unknown Attribute 22 is "Helium level."
Thank you,
craigr
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.18.14-unRAID] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
START OF INFORMATION SECTION
Device Model: WDC WD80EZAZ-11TDBA0
Serial Number: 7SJ3R0NW
LU WWN Device Id: 5 000cca 252dddec9
Firmware Version: 83.H0A83
User Capacity: 8,001,563,222,016 bytes [8.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 3.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Oct 18 18:00:41 2018 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
START OF READ SMART DATA SECTION
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 93) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: (1213) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
2 Throughput_Performance --S--- 128 128 054 - 116
3 Spin_Up_Time POS--- 162 162 024 - 453 (Average 361)
4 Start_Stop_Count -O--C- 100 100 000 - 12
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate -O-R-- 100 100 067 - 0
8 Seek_Time_Performance --S--- 128 128 020 - 18
9 Power_On_Hours -O--C- 100 100 000 - 118
10 Spin_Retry_Count -O--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 9
22 Unknown_Attribute PO---K 100 100 025 - 100
192 Power-Off_Retract_Count -O--CK 100 100 000 - 37
193 Load_Cycle_Count -O--C- 100 100 000 - 37
194 Temperature_Celsius -O---- 250 250 000 - 26 (Min/Max 20/29)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
_ K auto-keep | C event count _ R error rate | S speed/performance _ O updated online | P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL R/O 256 Device Statistics log
0x04 SL R/O 255 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x0c GPL R/O 5501 Pending Defects log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x12 GPL R/O 1 SATA NCQ Non-Data log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x15 GPL R/W 1 Rebuild Assist log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x24 GPL R/O 256 Current Device Internal Status Data log
0x25 GPL R/O 256 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 118 -
# 2 Short offline Completed without error 00% 111 -
# 3 Extended offline Completed without error 00% 105 -
# 4 Short offline Completed without error 00% 86 -
# 5 Short offline Completed without error 00% 20 -
# 6 Extended offline Completed without error 00% 19 -
# 7 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 0
Device State: Active (0)
Current Temperature: 26 Celsius
Power Cycle Min/Max Temperature: 21/29 Celsius
Lifetime Min/Max Temperature: 20/29 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/65 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (1)
Index Estimated Time Temperature Celsius
2 2018-10-18 15:53 22 *
... ..(113 skipped). .. *
116 2018-10-18 17:47 22 *
117 2018-10-18 17:48 23
118 2018-10-18 17:49 23
119 2018-10-18 17:50 24 *
120 2018-10-18 17:51 24 *
121 2018-10-18 17:52 24 *
122 2018-10-18 17:53 25
... ..( 3 skipped). ..
126 2018-10-18 17:57 25
127 2018-10-18 17:58 26 *
0 2018-10-18 17:59 26 *
1 2018-10-18 18:00 22 *
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) supported [please try: '-l defects']
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
smartctl-VENDOR-MODEL