Opened 10 years ago
Closed 10 years ago
#490 closed enhancement (fixed)
Add ADATA SSD SX900 512GB-DL2
Reported by: | spacedust | Owned by: | Christian Franke |
---|---|---|---|
Priority: | major | Milestone: | Release 6.4 |
Component: | all | Version: | 6.3 |
Keywords: | Cc: |
Description
Please add ADATA SSD SX900
smartctl 6.3 2014-07-26 r3976 [x86_64-w64-mingw32-win7-sp1] (sf-6.3-1) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: ADATA SSD SX900 512GB-DL2 Serial Number: 7D4120008765 LU WWN Device Id: 0 000000 000000000 Firmware Version: 5.8.2 User Capacity: 512 110 190 592 bytes [512 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat Nov 08 19:37:14 2014 SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7d) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x0025) SCT Status supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_ FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0032 120 120 050 Old_age Always - 1541893259264 5 Reallocated_Sector_Ct 0x0033 075 075 003 Pre-fail Always - 12 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 7 (213 126 0) 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 25 171 Unknown_Attribute 0x000a 100 100 000 Old_age Always - 0 172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 174 Unknown_Attribute 0x0030 000 000 000 Old_age Offline - 14 177 Wear_Leveling_Count 0x0000 000 000 000 Old_age Offline - 0 181 Program_Fail_Cnt_Total 0x000a 100 100 000 Old_age Always - 0 182 Erase_Fail_Count_Total 0x0032 100 100 000 Old_age Always - 0 187 Reported_Uncorrect 0x0012 001 001 000 Old_age Always - 46252 194 Temperature_Celsius 0x0022 028 053 000 Old_age Always - 28 (Min/Max 13/53) 195 Hardware_ECC_Recovered 0x001c 120 120 000 Old_age Offline - 1541893259264 196 Reallocated_Event_Count 0x0033 075 075 003 Pre-fail Always - 12 201 Unknown_SSD_Attribute 0x001c 120 120 000 Old_age Offline - 1541893259264 204 Soft_ECC_Correction 0x001c 120 120 000 Old_age Offline - 1541893259264 230 Unknown_SSD_Attribute 0x0013 100 100 000 Pre-fail Always - 100 231 Temperature_Celsius 0x0013 073 073 010 Pre-fail Always - 180388626433 233 Media_Wearout_Indicator 0x0032 000 000 000 Old_age Always - 374 234 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 831 241 Total_LBAs_Written 0x0032 000 000 000 Old_age Always - 831 242 Total_LBAs_Read 0x0032 000 000 000 Old_age Always - 511 SMART Error Log not supported SMART Self-test log structure revision number 0 Warning: ATA Specification requires self-test log structure revision number = 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
Change History (4)
comment:1 by , 10 years ago
Owner: | set to |
---|---|
Status: | new → assigned |
comment:2 by , 10 years ago
Milestone: | → Release 6.4 |
---|
comment:3 by , 10 years ago
Owner: | changed from | to
---|---|
Status: | assigned → accepted |
Note:
See TracTickets
for help on using tickets.
I will take it. It seems that description is available @ http://www.adata.com/AppStore/ADATA%20SSD%20Toolbox_UserGuide_V10_EN.pdf