Opened 27 hours ago
Last modified 4 hours ago
#1935 closed defect
Problems with S.M.A.R.T (OMV - Short self-test on /dev/nvme0n1) — at Version 3
Reported by: | NicolaiW | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | Release 7.4 |
Component: | smartd | Version: | |
Keywords: | nvme | Cc: |
Description (last modified by )
Hello everyone, for some time now, Open Media Vault has been sending me the following error message:
This message was generated by the smartd daemon running on: host name: omv-nas DNS domain: local The following warning/error was logged by the smartd daemon: Device: /dev/disk/by-id/nvme-CT4000P3SSD8_2342E88107D9, number of Error Log entries increased from 9 to 10 Device info: CT4000P3SSD8, S/N:2342E88107D9, FW:P9CR30A, NSID:1 For details see host's SYSLOG. You can also use the smartctl utility for further investigation. The original message about this issue was sent at Mon Feb 10 14:32:12 2025 CET Another message will be sent in 24 hours if the problem persists.
When I try to run a "Short self-test" on the "/dev/nvme0n1" manually, omv outputs the following:
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.12.9+bpo-amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, http://www.smartmontools.org === START OF INFORMATION SECTION === Model Number: CT4000P3SSD8 Serial Number: 2342E88107D9 Firmware Version: P9CR30A PCI Vendor/Subsystem ID: 0xc0a9 IEEE OUI Identifier: 0x00a075 Controller ID: 1 NVMe Version: 1.4 Number of Namespaces: 1 Namespace 1 Size/Capacity: 4,000,787,030,016 [4.00 TB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 6479a7 8440000039 Local Time is: Tue Feb 18 15:25:34 2025 CET Firmware Updates (0x12): 1 Slot, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Log Page Attributes (0x06): Cmd_Eff_Lg Ext_Get_Lg Maximum Data Transfer Size: 64 Pages Warning Comp. Temp. Threshold: 85 Celsius Critical Comp. Temp. Threshold: 95 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 6.00W 0.0000W - 0 0 0 0 0 0 1 + 3.00W 0.0000W - 0 0 0 0 0 0 2 + 1.50W 0.0000W - 0 0 0 0 0 0 3 - 0.0250W 0.0000W - 3 3 3 3 5000 1900 4 - 0.0030W - - 4 4 4 4 13000 100000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 1 1 - 4096 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 41 Celsius Available Spare: 100% Available Spare Threshold: 5% Percentage Used: 0% Data Units Read: 209,028 [107 GB] Data Units Written: 340,472 [174 GB] Host Read Commands: 535,891 Host Write Commands: 705,317 Controller Busy Time: 10 Power Cycles: 7 Power On Hours: 190 Unsafe Shutdowns: 0 Media and Data Integrity Errors: 0 Error Information Log Entries: 10 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 41 Celsius Temperature Sensor 2: 57 Celsius Temperature Sensor 8: 41 Celsius Error Information (NVMe Log 0x01, 16 of 16 entries) Num ErrCount SQId CmdId Status PELoc LBA NSID VS 0 10 0 0x4010 0x4005 0x028 0 0 -
Everything works perfectly with the SSD hard drive.
I'm still a bit of a newbie on this topic and would really appreciate some help with this problem.
Change History (3)
comment:1 by , 26 hours ago
Description: | modified (diff) |
---|
comment:2 by , 26 hours ago
Description: | modified (diff) |
---|
comment:3 by , 5 hours ago
Description: | modified (diff) |
---|
Note:
See TracTickets
for help on using tickets.