Opened 8 hours ago

Last modified 7 hours ago

#1935 new defect

Problems with S.M.A.R.T (OMV - Short self-test on /dev/nvme0n1)

Reported by: NicolaiW Owned by:
Priority: minor Milestone:
Component: all Version:
Keywords: omv, Short self-test, nvme0n1 Cc:

Description (last modified by NicolaiW)

Hello everyone, for some time now, Open Media Vault has been sending me the following error message:

"This message was generated by the smartd daemon running on:

host name: omv-nas

DNS domain: local

The following warning/error was logged by the smartd daemon:

Device: /dev/disk/by-id/nvme-CT4000P3SSD8_2342E88107D9, number of Error Log entries increased from 9 to 10

Device info:

CT4000P3SSD8, S/N:2342E88107D9, FW:P9CR30A, NSID:1

For details see host's SYSLOG.

You can also use the smartctl utility for further investigation.

The original message about this issue was sent at Mon Feb 10 14:32:12 2025 CET

Another message will be sent in 24 hours if the problem persists."

When I try to run a "Short self-test" on the "/dev/nvme0n1" manually, omv outputs the following:

"smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.12.9+bpo-amd64] (local build)

Copyright (C) 2002-22, Bruce Allen, Christian Franke, http://www.smartmontools.org

START OF INFORMATION SECTION

Model Number: CT4000P3SSD8

Serial Number: 2342E88107D9

Firmware Version: P9CR30A

PCI Vendor/Subsystem ID: 0xc0a9

IEEE OUI Identifier: 0x00a075

Controller ID: 1

NVMe Version: 1.4

Number of Namespaces: 1

Namespace 1 Size/Capacity: 4,000,787,030,016 [4.00 TB]

Namespace 1 Formatted LBA Size: 512

Namespace 1 IEEE EUI-64: 6479a7 8440000039

Local Time is: Tue Feb 18 15:25:34 2025 CET

Firmware Updates (0x12): 1 Slot, no Reset required

Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test

Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp

Log Page Attributes (0x06): Cmd_Eff_Lg Ext_Get_Lg

Maximum Data Transfer Size: 64 Pages

Warning Comp. Temp. Threshold: 85 Celsius

Critical Comp. Temp. Threshold: 95 Celsius

Supported Power States

St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat

0 + 6.00W 0.0000W - 0 0 0 0 0 0

1 + 3.00W 0.0000W - 0 0 0 0 0 0

2 + 1.50W 0.0000W - 0 0 0 0 0 0

3 - 0.0250W 0.0000W - 3 3 3 3 5000 1900

4 - 0.0030W - - 4 4 4 4 13000 100000

Supported LBA Sizes (NSID 0x1)

Id Fmt Data Metadt Rel_Perf

0 + 512 0 1

1 - 4096 0 0

START OF SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

SMART/Health Information (NVMe Log 0x02)

Critical Warning: 0x00

Temperature: 41 Celsius

Available Spare: 100%

Available Spare Threshold: 5%

Percentage Used: 0%

Data Units Read: 209,028 [107 GB]

Data Units Written: 340,472 [174 GB]

Host Read Commands: 535,891

Host Write Commands: 705,317

Controller Busy Time: 10

Power Cycles: 7

Power On Hours: 190

Unsafe Shutdowns: 0

Media and Data Integrity Errors: 0

Error Information Log Entries: 10

Warning Comp. Temperature Time: 0

Critical Comp. Temperature Time: 0

Temperature Sensor 1: 41 Celsius

Temperature Sensor 2: 57 Celsius

Temperature Sensor 8: 41 Celsius

Error Information (NVMe Log 0x01, 16 of 16 entries)

Num ErrCount SQId CmdId Status PELoc LBA NSID VS

0 10 0 0x4010 0x4005 0x028 0 0 -

END OF LINE"

Everything works perfectly with the SSD hard drive.

I'm still a bit of a newbie on this topic and would really appreciate some help with this problem.

Change History (2)

comment:1 by NicolaiW, 7 hours ago

Description: modified (diff)

comment:2 by NicolaiW, 7 hours ago

Description: modified (diff)
Note: See TracTickets for help on using tickets.