Description
Just seen an interesting fact on a hard drive with a current Power_On_Hours value of 65966. I launched an extended offline test (using -t long) and the LifeTime (hours) column does not show the real Power_On_Hours value:
=== START OF INFORMATION SECTION === Model Family: Western Digital Green Device Model: WDC WD20EARX-00PASB0 Serial Number: obfuscated LU WWN Device Id: 5 0014ee 25c9427f5 Firmware Version: 51.0AB51 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Thu Dec 31 15:56:48 2020 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (38400) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 370) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 173 167 021 Pre-fail Always - 6341 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 161 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 010 010 000 Old_age Always - 65966 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 161 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 40 193 Load_Cycle_Count 0x0032 153 153 000 Old_age Always - 142788 194 Temperature_Celsius 0x0022 128 110 000 Old_age Always - 22 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 429 - # 2 Extended offline Completed without error 00% 220 - # 3 Extended offline Completed without error 00% 63835 - # 4 Extended offline Completed without error 00% 21182 - # 5 Extended offline Completed without error 00% 971 - # 6 Short offline Completed without error 00% 836 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
It seems that the maximum Power_On_Hours value is 65535 (interestingly the same value as the maximum network port range). All values above that are shown as difference LifeTime (hours).
Is this a bug? Is this intended?
PS I Used smartctl 6.6 for this.
Change History (1)
comment:1 by , 4 years ago
Component: | all → smartctl |
---|---|
Keywords: | ata added |
Resolution: | → duplicate |
Status: | new → closed |
Type: | task → defect |
Note:
See TracTickets
for help on using tickets.
This is a limitation of the ATA self-test logs, see ticket #680.