Version 2 (modified by 15 years ago) ( diff ) | ,
---|
Linked from Supported_USB-Devices
Written on enclosure:
3907A MDL: WD1200U017-004 S/N: WXC207121825
% lsusb -d 1058:0702 -v Bus 003 Device 003: ID 1058:0702 Western Digital Technologies, Inc. Passport External HDD Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x1058 Western Digital Technologies, Inc. idProduct 0x0702 Passport External HDD bcdDevice 1.02 iManufacturer 1 Western Digital iProduct 2 External HDD iSerial 3 575843323037313231383235 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk (Zip) iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered
% sudo smartctl -a /dev/sdc smartctl 5.39 2009-12-09 r2995 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Western Digital Scorpio Blue Serial ATA family Device Model: WDC WD1200BEVS-00RST0 Serial Number: WD-WXC207121825 Firmware Version: 04.01G04 User Capacity: 120,034,123,776 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Tue Jan 19 23:07:36 2010 EET SMART support is: Available - device has SMART capability. SMART support is: Enabled Error SMART Status command failed Please get assistance from http://smartmontools.sourceforge.net/ A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options.
% sudo smartctl -T permissive -a /dev/sdc smartctl 5.39 2009-12-09 r2995 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Western Digital Scorpio Blue Serial ATA family Device Model: WDC WD1200BEVS-00RST0 Serial Number: WD-WXC207121825 Firmware Version: 04.01G04 User Capacity: 120,034,123,776 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Tue Jan 19 23:09:13 2010 EET SMART support is: Available - device has SMART capability. SMART support is: Enabled Error SMART Status command failed Please get assistance from http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (5100) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 67) minutes. Conveyance self-test routine recommended polling time: ( 6) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0003 155 147 021 Pre-fail Always - 3216 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 121 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 604 10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 051 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 101 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 22 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 840 194 Temperature_Celsius 0x0022 117 103 000 Old_age Always - 30 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0009 100 253 051 Pre-fail Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 604 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
Note:
See TracWiki
for help on using the wiki.