Changes between Version 29 and Version 30 of FAQ


Ignore:
Timestamp:
Mar 24, 2011, 2:05:41 PM (14 years ago)
Author:
JoB
Comment:

Nope, LucidPORT firmware issue is not fixed even on firmware 2447! Do not trust their changelog...

Legend:

Unmodified
Added
Removed
Modified
  • FAQ

    v29 v30  
    148148compliance means that they tend to only support the bare minimum of
    149149commands needed for device operation (i.e. SMART support is an unsupported
    150 extra). Hopefully external USB and !Firewire devices will support SAT in
     150extra). Hopefully external USB and Firewire devices will support SAT in
    151151the future, see below. Some USB device based on cypress chips support a
    152152proprietary protocol (ATACB) that allow to send raw ATA commands (i.e.
     
    448448=== 'Error SMART Status command failed' What's the meaning of this {{{smartctl}}} message? ===
    449449
    450 The SMART status command (health monitoring) is not working properly. This is found on USB 3.0 enclosures based on LucidPORT USB300 bridge with firmware 2370 or earlier. Firmware 2382 and later fix this error. Contact both your enclosure manufacturer and LucidPORT to obtain a working firmware.
     450The SMART status command (health monitoring) is not working properly. This is found on USB 3.0 enclosures based on LucidPORT USB300 bridge with firmware 2447 or earlier. Firmware 2580 may fix this error. Contact both your enclosure manufacturer and LucidPORT to obtain a working firmware.
    451451
    452452----