     448=== 'Error SMART Status command failed' What's the meaning of this {{{smartctl}}} message? ===
     449
     450The SMART status command (health monitoring) is not working properly. This is found on USB 3.0 enclosures based on LucidPORT USB300 bridge with firmware 2370 or earlier. Firmware 2382 and later fix this error. Contact both your enclosure manufacturer and LucidPORT to obtain a working firmware.
     451
     452----
     453
    448454=== 'Warning: ATA error count 9 inconsistent with error log pointer 5' What's the meaning of this {{{smartctl}}} message? ===