Opened 7 years ago

Last modified 6 years ago

#904 new enhancement

ADATA SP580 — at Initial Version

Reported by: Knitebane Owned by:
Priority: minor Milestone: unscheduled
Component: drivedb Version: 6.5
Keywords: ssd Cc:

Description

smartctl 6.2 2013-07-26 r3841 [x86_64-linux-4.4.0-96-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

START OF INFORMATION SECTION

Device Model: ADATA SP580
Firmware Version: V3.10
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-3 (unknown minor revision code: 0x011b)
SATA Version is: SATA >3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Sep 30 22:47:41 2017 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable

START OF READ SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status: (0x02) Offline data collection activity

was completed without error.
Auto Offline Data Collection: Disabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever
been run.

Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x35) SMART execute Offline immediate.

No Auto Offline data collection support.
Abort Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
No Selective Self-test supported.

SMART capabilities: (0x0002) Does not save SMART data before

entering power-saving mode.
Supports SMART auto save timer.

Error logging capability: (0x00) Error logging NOT supported.

General Purpose Logging supported.

Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 1) minutes.
Conveyance self-test routine
recommended polling time: ( 1) minutes.

SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE

5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours PO--CK 100 100 010 - 0

12 Power_Cycle_Count PO--CK 100 100 010 - 1

161 Unknown_Attribute PO--CK 100 100 010 - 0
164 Unknown_Attribute PO--CK 100 100 010 - 0
165 Unknown_Attribute PO--CK 100 100 010 - 0
166 Unknown_Attribute PO--CK 100 100 010 - 0
167 Unknown_Attribute PO--CK 100 100 010 - 0
169 Unknown_Attribute PO--CK 100 100 010 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 010 - 0
177 Wear_Leveling_Count PO--CK 100 100 010 - 0
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 010 - 0
192 Power-Off_Retract_Count PO--CK 100 100 010 - 0
194 Temperature_Celsius PO--CK 100 100 010 - 43
195 Hardware_ECC_Recovered PO--CK 100 100 010 - 0
199 UDMA_CRC_Error_Count PO--CK 100 100 010 - 0
241 Total_LBAs_Written PO--CK 100 100 010 - 0
242 Total_LBAs_Read PO--CK 100 100 010 - 69
243 Unknown_Attribute PO--CK 100 100 010 - 0
244 Unknown_Attribute PO--CK 100 100 010 - 0
245 Unknown_Attribute PO--CK 100 100 010 - 0
246 Unknown_Attribute PO--CK 100 100 010 - 0
250 Read_Error_Retry_Rate PO--CK 100 100 010 - 0
251 Unknown_Attribute PO--CK 100 100 010 - 0
252 Unknown_Attribute PO--CK 100 100 010 - 0
253 Unknown_Attribute PO--CK 100 100 010 - 0
254 Unknown_SSD_Attribute PO--CK 100 100 010 - 0

_ K auto-keep
| C event count
_ R error rate
| S speed/performance
_ O updated online

| P prefailure warning

General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x10 GPL,SL R/O 1 NCQ Command Error log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

SMART Error Log not supported

SMART Extended Self-test Log (GP Log 0x07) not supported

SMART Self-test Log not supported

Selective Self-tests/Logging not supported

SCT Commands not supported

Device Statistics (GP Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11) not supported

Change History (1)

by Knitebane, 7 years ago

Attachment: smartctl-ADATA-SP580.txt added
Note: See TracTickets for help on using tickets.