Opened 8 years ago
Last modified 8 years ago
#817 closed defect
Smard : Failed to read Temperature — at Version 1
Reported by: | hetsalgood | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | Release 6.6 |
Component: | smartd | Version: | 6.5 |
Keywords: | scsi | Cc: |
Description (last modified by )
I received the below messages at every 30 minutes.
And I'm not changed smartd.conf file.
HPE DL580 Gen9 & SUSE 12 SP1
smartd[64688]: Device: /dev/sda, failed to read Temperature smartd[64688]: Device: /dev/sdb, failed to read Temperature smartd[64688]: Device: /dev/sdc, failed to read Temperature smartd[64688]: Device: /dev/sdd, failed to read Temperature smartctl -a /dev/sda smartctl 6.2 2013-11-07 r3856 [x86_64-linux-3.12.69-60.64.32-default] (SUSE RPM) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Vendor: HP Product: LOGICAL VOLUME Revision: 4.04 User Capacity: 1,200,210,141,184 bytes [1.20 TB] Logical block size: 512 bytes Logical Unit id: 0x600508b1001ce7f861935ed955ece6be Serial number: 0014380400C02F0 Device type: disk Local Time is: Tue Mar 14 16:05:07 2017 KST SMART support is: Available - device has SMART capability. SMART support is: Enabled Temperature Warning: Disabled or Not Supported === START OF READ SMART DATA SECTION === SMART Health Status: OK Error Counter logging not supported Device does not support Self Test logging
Note:
See TracTickets
for help on using tickets.