| 5 | |
| 6 | Full output: |
| 7 | |
| 8 | smartctl 6.7 2018-11-13 r4834 [x86_64-linux-3.10.0-862.3.3.el7.x86_64] (local build) |
| 9 | Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org |
| 10 | |
| 11 | === START OF INFORMATION SECTION === |
| 12 | Device Model: KINGSTON SA400S37480G |
| 13 | Serial Number: 50026B777301E2CD |
| 14 | LU WWN Device Id: 5 000000 000000000 |
| 15 | Firmware Version: SBFK10D7 |
| 16 | User Capacity: 480,103,981,056 bytes [480 GB] |
| 17 | Sector Size: 512 bytes logical/physical |
| 18 | Rotation Rate: Solid State Device |
| 19 | Form Factor: 2.5 inches |
| 20 | Device is: Not in smartctl database [for details use: -P showall] |
| 21 | ATA Version is: ACS-4 (minor revision not indicated) |
| 22 | SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s) |
| 23 | Local Time is: Wed Nov 21 15:51:43 2018 MSK |
| 24 | SMART support is: Available - device has SMART capability. |
| 25 | SMART support is: Enabled |
| 26 | |
| 27 | === START OF READ SMART DATA SECTION === |
| 28 | SMART overall-health self-assessment test result: PASSED |
| 29 | |
| 30 | General SMART Values: |
| 31 | Offline data collection status: (0x00) Offline data collection activity |
| 32 | was never started. |
| 33 | Auto Offline Data Collection: Disabled. |
| 34 | Self-test execution status: ( 0) The previous self-test routine completed |
| 35 | without error or no self-test has ever |
| 36 | been run. |
| 37 | Total time to complete Offline |
| 38 | data collection: (65535) seconds. |
| 39 | Offline data collection |
| 40 | capabilities: (0x79) SMART execute Offline immediate. |
| 41 | No Auto Offline data collection support. |
| 42 | Suspend Offline collection upon new |
| 43 | command. |
| 44 | Offline surface scan supported. |
| 45 | Self-test supported. |
| 46 | Conveyance Self-test supported. |
| 47 | Selective Self-test supported. |
| 48 | SMART capabilities: (0x0003) Saves SMART data before entering |
| 49 | power-saving mode. |
| 50 | Supports SMART auto save timer. |
| 51 | Error logging capability: (0x01) Error logging supported. |
| 52 | General Purpose Logging supported. |
| 53 | Short self-test routine |
| 54 | recommended polling time: ( 4) minutes. |
| 55 | Extended self-test routine |
| 56 | recommended polling time: ( 32) minutes. |
| 57 | Conveyance self-test routine |
| 58 | recommended polling time: ( 8) minutes. |
| 59 | |
| 60 | SMART Attributes Data Structure revision number: 16 |
| 61 | Vendor Specific SMART Attributes with Thresholds: |
| 62 | ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE |
| 63 | 1 Raw_Read_Error_Rate 0x000a 100 100 000 Old_age Always - 0 |
| 64 | 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 13201 |
| 65 | 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 7 |
| 66 | 167 Unknown_Attribute 0x0022 100 100 000 Old_age Always - 0 |
| 67 | 168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0 |
| 68 | 169 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 10 |
| 69 | 170 Unknown_Attribute 0x0013 100 100 010 Pre-fail Always - 20 |
| 70 | 172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 |
| 71 | 173 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 13500752 |
| 72 | 181 Program_Fail_Cnt_Total 0x0012 100 100 000 Old_age Always - 0 |
| 73 | 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 |
| 74 | 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 5 |
| 75 | 194 Temperature_Celsius 0x0023 080 062 000 Pre-fail Always - 20 (Min/Max 17/38) |
| 76 | 196 Reallocated_Event_Count 0x0000 100 100 000 Old_age Offline - 0 |
| 77 | 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0 |
| 78 | 218 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 |
| 79 | 231 Temperature_Celsius 0x0013 100 100 000 Pre-fail Always - 79 |
| 80 | 233 Media_Wearout_Indicator 0x0013 100 100 000 Pre-fail Always - 77857 |
| 81 | 241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 82489 |
| 82 | 242 Total_LBAs_Read 0x0012 100 100 000 Old_age Always - 69347 |
| 83 | 244 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 206 |
| 84 | 245 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 336 |
| 85 | 246 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 18016064 |
| 86 | |
| 87 | SMART Error Log Version: 1 |
| 88 | No Errors Logged |
| 89 | |
| 90 | SMART Self-test log structure revision number 1 |
| 91 | Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error |
| 92 | # 1 Extended offline Completed without error 00% 13136 - |
| 93 | |
| 94 | SMART Selective self-test log data structure revision number 0 |
| 95 | Note: revision number not 1 implies that no selective self-test has ever been run |
| 96 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS |
| 97 | 1 0 0 Not_testing |
| 98 | 2 0 0 Not_testing |
| 99 | 3 0 0 Not_testing |
| 100 | 4 0 0 Not_testing |
| 101 | 5 0 0 Not_testing |
| 102 | Selective self-test flags (0x0): |
| 103 | After scanning selected spans, do NOT read-scan remainder of disk. |
| 104 | If Selective self-test is pending on power-up, resume after 0 minute delay. |