#347 closed defect (invalid)
invalid SMART checksum bug
Reported by: | anemmer | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | |
Component: | smartctl | Version: | 5.39.1 |
Keywords: | Cc: |
Description
I am getting an "invalid SMART checksum" error when I run smartctl and there is not documentation for it and I can't find anything on the web about it so I think it may be a bug. Please investigate. Thank you.
Change History (4)
comment:1 by , 10 years ago
- Message itself indicates that SMART data coming from drive has uncorrect chipset. This could be caused by different reasons, including firmware/drive issues, OS or controller bug.
- If you want some help please provide more details about your OS and hardware.
- Before reporting please update to the recent smartmontools version and if bug is reproducible - send smartctl full output to this ticket.
comment:2 by , 10 years ago
Keywords: | invalid smart checksum bug removed |
---|
The "invalid SMART checksum" warning is often reported for still empty SMART error or self-test logs. This is harmless and could be ignored.
Please provide a sample output as attachment(!) to this ticket.
comment:3 by , 10 years ago
smartctl 5.39.1 2010-01-28 r3054 [i486-slackware-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION === Model Family: Hitachi Deskstar 7K80 series Device Model: HDS728080PLAT20 Serial Number: PFD219SYU97E1E Firmware Version: PF2OA2AA User Capacity: 82,348,277,760 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1 Local Time is: Tue Aug 19 11:56:41 2014 MST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (1828) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 31) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0 3 Spin_Up_Time 0x0007 106 106 024 Pre-fail Always - 197 (Average 180) 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 175 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail Offline - 0 9 Power_On_Hours 0x0012 095 095 000 Old_age Always - 35999 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 175 192 Power-Off_Retract_Count 0x0032 099 099 050 Old_age Always - 1667 193 Load_Cycle_Count 0x0012 099 099 050 Old_age Always - 1667 194 Temperature_Celsius 0x0002 144 144 000 Old_age Always - 38 (Lifetime Min/Max 17/46) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 35914 - # 2 Short offline Completed without error 00% 35913 - Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum. SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
comment:4 by , 10 years ago
Resolution: | → invalid |
---|---|
Status: | new → closed |
This is a harmless drive firmware bug which could be safely ignored. It is not a smartctl bug.
The warning may possibly disappear when the Selective Self-Test log is no longer empty. The warning could also be suppressed with the -b ignore
option, see man page.
Please note that your smartctl version 5.39.1 is very old. The 5.39 drive database branch is no longer updated since 2011.
BTW: For future problem reports PLEASE don't paste smartctl sample output to a ticket comment. Use an attachment or alternatively Wiki Formatting syntax for Preformatted Text
, thanks.