Opened 12 years ago
Closed 12 years ago
#254 closed defect (wontfix)
Smartctl 5.38 testing SAS HDD issue
Reported by: | jackson4015 | Owned by: | somebody |
---|---|---|---|
Priority: | major | Milestone: | |
Component: | smartctl | Version: | 5.38 |
Keywords: | linux | Cc: | jackson4015 |
Description
Server+ LSI RAID card 1064E+ Seagate new Gen of 10K HDD:ST 900MM0006
RAID 1 seeting on 2 x SAS HDD;
Use smartctlv5.43 to do test DST, skip;
report error: not supported
But for centos/federo, no such issue;
Change History (6)
comment:1 by , 12 years ago
Cc: | added |
---|---|
Component: | all → smartctl |
Summary: | Smartctl 5.43 testing issue in Suse 10 → Smartctl 5.38 testing SAS HDD issue |
Version: | 5.43 → 5.38 |
comment:2 by , 12 years ago
follow-ups: 4 5 comment:3 by , 12 years ago
Keywords: | linux added; compatibility issue removed |
---|
Description is same as of ticket #255, Please update description, update smartctl and repeat the test. Smartctl 5.38 is more than 4 years old.
comment:4 by , 12 years ago
Replying to chrfranke:
Description is same as of ticket #255, Please update description, update smartctl and repeat the test. Smartctl 5.38 is more than 4 years old.
Sorry,send issue description ticket#255 for twice, 5.38 issue detail:
Use 5.38 to test Seagate new SAS 10k HDD:ST900MM0006
OS:suse 11 or RHEL 5:
Health test fail & report error:
scsi response fails sanity test,IE page
Tried a new ver, had no similar issue, could not understand why it happened on v5.38,
many old OS integrated v5.38, so need to find the root cause,otherwise ST900MM0006
could not be used on them.
Try to provide smartctl debug infor. on next Mon.
comment:5 by , 12 years ago
Replying to chrfranke:
As V5.43 or higher has no such issue,while other SAS HDDs are OK under V5.38
except this new Gen of 10K SAS,interesting;
Hope figure out whether it is a tool bug or HDD FW issue.
thx!
comment:6 by , 12 years ago
Resolution: | → wontfix |
---|---|
Status: | new → closed |
If the problem can only be reproduced with 5.38, we cannot provide much help, sorry. You might want to contact the package maintainers and request updated packages.
Use 5.38 to test Seagate new SAS 10k HDD:ST900MM0006
OS:suse 11 or RHEL 5:
Health test fail & report error:
scsi response fails sanity test,IE page
Hope to know the reason.