Opened 4 months ago
Last modified 4 months ago
#1861 new defect
Double entry in drivedb for 'INTEL SSDSC2BA200G4'
Reported by: | Stephan Trebs | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | undecided |
Component: | drivedb | Version: | 7.4 |
Keywords: | ssd | Cc: |
Description (last modified by )
Intel SSD DC 3710 (INTEL SSDSC2BA200G4) is detected as 'Intel 730 and DC S35x0/3610/3700 Series SSDs' by this entry in drivedb:
---snip---
{ "Intel 730 and DC S35x0/3610/3700 Series SSDs", // tested with INTEL SSDSC2BP480G4, SSDSC2BB120G4/D2010355, // INTEL SSDSC2BB800G4T, SSDSC2BA200G3/5DV10250, SSDSC2BB080G6/G2010130, SSDSC2BX200G4/G2010110, // INTEL SSDSC2BB016T6/G2010140, SSDSC2BX016T4/G2010140, SSDSC2BB150G7/N2010101, // INTEL SSDSC2BB480H4/D2010380, INTEL SSDSC2BB240G4C/D201FJ14, INTEL SSDSC2BA800G3E/5DV10250 "INTEL SSDSC(1N|2B)[ABPX]((080|100|120|150|160|200|240|300|400|480|600|800)[GH][3467][CERT]?|(012|016)T[46])", // A = S3700, B*4 = S3500, B*6 = S3510, P = 730, X = S3610 // Dell ships drives with model of the form SSDSC2BB120G4R "", "", //"-v 3,raw16(avg16),Spin_Up_Time " //"-v 4,raw48,Start_Stop_Count " //"-v 5,raw16(raw16),Reallocated_Sector_Ct " //"-v 9,raw24(raw8),Power_On_Hours " //"-v 12,raw48,Power_Cycle_Count " "-v 170,raw48,Available_Reservd_Space " "-v 171,raw48,Program_Fail_Count " "-v 172,raw48,Erase_Fail_Count " "-v 174,raw48,Unsafe_Shutdown_Count " "-v 175,raw16(raw16),Power_Loss_Cap_Test " "-v 183,raw48,SATA_Downshift_Count " //"-v 184,raw48,End-to-End_Error " //"-v 187,raw48,Reported_Uncorrect " "-v 190,tempminmax,Temperature_Case " "-v 192,raw48,Unsafe_Shutdown_Count " "-v 194,tempminmax,Temperature_Internal " //"-v 197,raw48,Current_Pending_Sector " "-v 199,raw48,CRC_Error_Count " "-v 225,raw48,Host_Writes_32MiB " "-v 226,raw48,Workld_Media_Wear_Indic " // Timed Workload Media Wear Indicator (percent*1024) "-v 227,raw48,Workld_Host_Reads_Perc " // Timed Workload Host Reads Percentage "-v 228,raw48,Workload_Minutes " // 226,227,228 can be reset by 'smartctl -t vendor,0x40' //"-v 232,raw48,Available_Reservd_Space " //"-v 233,raw48,Media_Wearout_Indicator " "-v 234,raw24/raw32:04321,Thermal_Throttle " "-v 241,raw48,Host_Writes_32MiB " "-v 242,raw48,Host_Reads_32MiB " "-v 243,raw48,NAND_Writes_32MiB " // S3510/3610 "-F xerrorlba" // tested with SSDSC2BB600G4/D2010355 },
---snip---
There is a second different entry that could match but it is never used:
---snip---
{ "Intel 3710 Series SSDs", // INTEL SSDSC2BA200G4R/G201DL2B (dell) "INTEL SSDSC2BA(200G|400G|800G|012T)4.?", "", "", "-v 9,msec24hour32,Power_On_Hours_and_Msec " "-v 170,raw48,Available_Reservd_Space " "-v 171,raw48,Program_Fail_Count " "-v 172,raw48,Erase_Fail_Count " "-v 174,raw48,Unexpect_Power_Loss_Ct " "-v 183,raw48,SATA_Downshift_Count " "-v 187,raw48,Uncorrectable_Error_Cnt " "-v 225,raw48,Host_Writes_32MiB " "-v 226,raw48,Workld_Media_Wear_Indic " "-v 227,raw48,Workld_Host_Reads_Perc " "-v 228,raw48,Workload_Minutes " "-v 234,raw24/raw32:04321,Thermal_Throttle " "-v 243,raw48,NAND_Writes_32MiB " },
---snip---
So the second entry can probably be removed because it is never used.
Change History (2)
comment:1 by , 4 months ago
Description: | modified (diff) |
---|
comment:2 by , 4 months ago
Keywords: | ssd added |
---|---|
Milestone: | → undecided |
Type: | task → defect |
Note:
See TracTickets
for help on using tickets.
Thanks for catching. Needs some historic research as the attribute set from the second entry differs slightly and the first entry does not mention
3710
. Perhaps the second entry is from some Dell OEM variant with different firmware.