Changes between Initial Version and Version 1 of Ticket #1850, comment 2


Ignore:
Timestamp:
Jun 30, 2024, 4:30:39 PM (3 months ago)
Author:
Matalonder

Legend:

Unmodified
Added
Removed
Modified
  • Ticket #1850, comment 2

    initial v1  
    33> Note that an over-temperature event should be reported by bit 1 of the Critical Warning byte which is checked if -H is set.
    44
    5 Is that decided by device firmware or can be customized?
     5Is the temperature level used for that set in device firmware, or can be customized?
    66
    77I kind of don't trust the device in this. It's spec says "max work temp" is 70°, but it seems to report it's happy with up to 85° (which is "max storage temp" by spec). And I'd like to have an earlier warning, anyway, which is why I set it to 65°.