Opened 21 months ago

Last modified 16 months ago

#1700 closed enhancement

INTENSO Performance 500GB — at Initial Version

Reported by: jdi-43 Owned by:
Priority: minor Milestone: Release 7.4
Component: drivedb Version:
Keywords: ssd Cc:

Description

smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.85-1-pve] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org

START OF INFORMATION SECTION

Device Model: Intenso SSD Sata III
Serial Number: AA000000000000001911
Firmware Version: V0303B0
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-3 T13/2161-D revision 4
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Mar 9 09:25:43 2023 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable

START OF READ SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status: (0x02) Offline data collection activity

was completed without error.
Auto Offline Data Collection: Disabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever
been run.

Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.

No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.

SMART capabilities: (0x0002) Does not save SMART data before

entering power-saving mode.
Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SCT capabilities: (0x0001) SCT Status supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE

1 Raw_Read_Error_Rate -O--CK 100 100 050 - 0
5 Reallocated_Sector_Ct -O--CK 100 100 050 - 0
9 Power_On_Hours -O--CK 100 100 050 - 119

12 Power_Cycle_Count -O--CK 100 100 050 - 13

160 Unknown_Attribute -O--CK 100 100 050 - 0
161 Unknown_Attribute PO--CK 100 100 050 - 100
163 Unknown_Attribute -O--CK 100 100 050 - 19
164 Unknown_Attribute -O--CK 100 100 050 - 2649
165 Unknown_Attribute -O--CK 100 100 050 - 23
166 Unknown_Attribute -O--CK 100 100 050 - 2
167 Unknown_Attribute -O--CK 100 100 050 - 6
168 Unknown_Attribute -O--CK 100 100 050 - 5050
169 Unknown_Attribute -O--CK 100 100 050 - 100
175 Program_Fail_Count_Chip -O--CK 100 100 050 - 0
176 Erase_Fail_Count_Chip -O--CK 100 100 050 - 0
177 Wear_Leveling_Count -O--CK 100 100 050 - 0
178 Used_Rsvd_Blk_Cnt_Chip -O--CK 100 100 050 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 050 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 050 - 0
192 Power-Off_Retract_Count -O--CK 100 100 050 - 12
194 Temperature_Celsius -O---K 100 100 050 - 36
195 Hardware_ECC_Recovered -O--CK 100 100 050 - 0
196 Reallocated_Event_Count -O--CK 100 100 050 - 0
197 Current_Pending_Sector -O--CK 100 100 050 - 0
198 Offline_Uncorrectable -O--CK 100 100 050 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 050 - 0
232 Available_Reservd_Space -O--CK 100 100 050 - 100
241 Total_LBAs_Written ----CK 100 100 050 - 27347
242 Total_LBAs_Read ----CK 100 100 050 - 23118
245 Unknown_Attribute -O--CK 100 100 050 - 32508

_ K auto-keep
| C event count
_ R error rate
| S speed/performance
_ O updated online

| P prefailure warning

General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x24 GPL R/O 88 Current Device Internal Status Data log
0x25 GPL R/O 32 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log

SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 118 -

Selective Self-tests/Logging not supported

SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 36/36 Celsius
Lifetime Min/Max Temperature: 23/50 Celsius
Specified Max Operating Temperature: 100 Celsius
Under/Over Temperature Limit Count: 0/0

SCT Data Table command not supported

SCT Error Recovery Control command not supported

Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 13 --- Lifetime Power-On Resets
0x01 0x010 4 119 --- Power-on Hours
0x01 0x018 6 1792260419 --- Logical Sectors Written
0x01 0x020 6 11420321 --- Number of Write Commands
0x01 0x028 6 1515088840 --- Logical Sectors Read
0x01 0x030 6 5975656 --- Number of Read Commands
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 0 --- Percentage Used Endurance Indicator

|_ C monitored condition met
D supports DSN

|_ N normalized value

Pending Defects log (GP Log 0x0c) not supported

SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x000a 4 5 Device-to-host register FISes sent due to a COMRESET

Change History (1)

by jdi-43, 21 months ago

aufgrund trac-text-interpretation, nochmal als plain ascii