Opened 3 years ago

Last modified 12 months ago

#1569 closed enhancement

add to drivedb: Sandisk SD9SN8W — at Initial Version

Reported by: Vadmin Owned by:
Priority: minor Milestone: Release 7.5
Component: drivedb Version: 7.1
Keywords: ssd Cc: vadimka83@…

Description

Could you add the following disk reference in the smartctl database ?
Here is the smartctl -a output:

START OF INFORMATION SECTION

Device Model: SanDisk SD9SN8W128G1020
Serial Number: ....
LU WWN Device Id: 5 001b44 8b994b732
Firmware Version: X6101020
User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: M.2
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Feb 15 01:21:47 2022 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

START OF READ SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status: (0x00) Offline data collection activity

was never started.
Auto Offline Data Collection: Disabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever
been run.

Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.

No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode.
Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.

SMART Attributes Data Structure revision number: 4
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

5 Reallocated_Sector_Ct 0x0032 100 100 --- Old_age Always - 0
9 Power_On_Hours 0x0032 100 100 --- Old_age Always - 26536

12 Power_Cycle_Count 0x0032 100 100 --- Old_age Always - 25

165 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 1356418753
166 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 104
167 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 34
168 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 172
169 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 102
170 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0
171 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0
172 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0
173 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 145
174 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 5
184 End-to-End_Error 0x0032 100 100 --- Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 --- Old_age Always - 0
188 Command_Timeout 0x0032 100 100 --- Old_age Always - 0
194 Temperature_Celsius 0x0022 064 070 --- Old_age Always - 36 (Min/Max 27/70)
199 UDMA_CRC_Error_Count 0x0032 100 100 --- Old_age Always - 0
230 Unknown_SSD_Attribute 0x0032 100 100 --- Old_age Always - 44118142232608
232 Available_Reservd_Space 0x0033 100 100 004 Pre-fail Always - 100
233 Media_Wearout_Indicator 0x0032 100 100 --- Old_age Always - 18443
234 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 56778
241 Total_LBAs_Written 0x0030 253 253 --- Old_age Offline - 40598
242 Total_LBAs_Read 0x0030 253 253 --- Old_age Offline - 39691
244 Unknown_Attribute 0x0032 000 100 --- Old_age Always - 0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported

Change History (0)

Note: See TracTickets for help on using tickets.