Opened 14 years ago

Closed 14 years ago

#153 closed enhancement (fixed)

missing USB bridge for LaCie Drive

Reported by: thomasvs Owned by: Christian Franke
Priority: minor Milestone: Release 5.41
Component: drivedb Version: 5.40
Keywords: Cc:

Description

[root@davedina ~]# smartctl --all /dev/sde -d auto
smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

/dev/sde: Unknown USB bridge [0x059f:0x1029 (0x100)]
Smartctl: please specify device type with the -d option.

Use smartctl -h to get a usage summary

[root@davedina ~]# smartctl --all /dev/sde -d sat
smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

START OF INFORMATION SECTION

Model Family: Hitachi Deskstar 7K2000
Device Model: Hitachi HDS722020ALA330
Serial Number: JK1121YAG4220S
Firmware Version: JKAOA10D
User Capacity: 2,000,398,934,016 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 4
Local Time is: Fri Mar 4 16:45:52 2011 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

START OF READ SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status: (0x84) Offline data collection activity

was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever
been run.

Total time to complete Offline
data collection: (22036) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.

Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode.
Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 255) minutes.
SCT capabilities: (0x003d) SCT Status supported.

SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0
2 Throughput_Performance 0x0005 134 134 054 Pre-fail Offline - 97
3 Spin_Up_Time 0x0007 114 114 024 Pre-fail Always - 632 (Average 635)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 56
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 1
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 112 112 020 Pre-fail Offline - 39
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 1595

10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 53

192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 56
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 56
194 Temperature_Celsius 0x0002 253 253 000 Old_age Always - 21 (Min/Max 17/58)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 1
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0

SMART Error Log Version: 0
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1

SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS

1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing

Selective self-test flags (0x0):

After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.

Works with SAT, so I think you can add it safely.

Change History (4)

comment:1 by Christian Franke, 14 years ago

Component: alldrivedb
Milestone: Release 5.41
Priority: majorminor
Type: defectenhancement

comment:2 by Christian Franke, 14 years ago

Owner: changed from somebody to manfred99
Status: newassigned

comment:3 by Christian Franke, 14 years ago

Owner: changed from manfred99 to Christian Franke
Status: assignedaccepted

comment:4 by Christian Franke, 14 years ago

Resolution: fixed
Status: acceptedclosed