Opened 4 years ago

Closed 11 months ago

Last modified 11 months ago

#1351 closed enhancement (fixed)

InnoDisk Corp. - EDC 1SE2 H 64GB

Reported by: softmove Owned by: Christian Franke
Priority: minor Milestone: Release 7.2
Component: drivedb Version:
Keywords: ssd Cc:

Description

https://www.innodisk.com/en/products/flash-storage/embedded-disk-card_edc/edc_1se2_horizontal#tab1

smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-9-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     InnoDisk Corp. - EDC 1SE2 H 64GB
Firmware Version: 131216
User Capacity:    64.030.244.864 bytes [64,0 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   [No Information Found]
Local Time is:    Fri Jul 17 15:02:47 2020 CEST
SMART support is: Ambiguous - ATA IDENTIFY DEVICE words 85-87 don't show if SMART is enabled.
                  Checking to be sure by trying SMART RETURN STATUS command.
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Disabled
Rd look-ahead is: Unavailable
Write cache is:   Disabled
DSN feature is:   Unavailable
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Disabled.
Total time to complete Offline 
data collection: 		(    1) seconds.
Offline data collection
capabilities: 			 (0x00) 	Offline data collection not supported.
SMART capabilities:            (0x0002)	Does not save SMART data before
					entering power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x00)	Error logging NOT supported.
					No General Purpose Logging support.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     ------   100   100   050    -    0
  5 Reallocated_Sector_Ct   -O----   100   100   050    -    0
 12 Power_Cycle_Count       ------   100   100   050    -    63
160 Unknown_Attribute       ------   100   100   050    -    0
161 Unknown_Attribute       ------   100   100   050    -    591
162 Unknown_Attribute       ------   100   100   050    -    238
163 Unknown_Attribute       ------   100   100   050    -    37
164 Unknown_Attribute       ------   100   100   050    -    7203731
165 Unknown_Attribute       ------   100   100   050    -    917
166 Unknown_Attribute       ------   100   100   050    -    849
167 Unknown_Attribute       ------   100   100   050    -    884
192 Power-Off_Retract_Count ------   100   100   050    -    0
194 Temperature_Celsius     ------   100   100   000    -    46 (Min/Max 39/66)
195 Hardware_ECC_Recovered  ------   100   100   050    -    0
196 Reallocated_Event_Count ------   100   100   050    -    0
198 Offline_Uncorrectable   ------   000   000   000    -    0
199 UDMA_CRC_Error_Count    ------   100   100   050    -    0
241 Total_LBAs_Written      -O--CK   100   100   050    -    123704
242 Total_LBAs_Read         -O--CK   100   100   050    -    282928
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

Read SMART Log Directory failed: scsi error badly formed scsi parameters

ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: scsi error badly formed scsi parameters
Read GP Log Directory failed

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

Read SMART Error Log failed: scsi error badly formed scsi parameters

SMART Extended Self-test Log (GP Log 0x07) not supported

Read SMART Self-test Log failed: scsi error badly formed scsi parameters

Selective Self-tests/Logging not supported

SCT Commands not supported

Device Statistics (GP/SMART Log 0x04) not supported

Pending Defects log (GP Log 0x0c) not supported

SATA Phy Event Counters (GP Log 0x11) not supported


Change History (12)

comment:1 by softmove, 4 years ago

There is also a detailed manual available for this module. Unfortunately this is too big for the ticket upload (4MB). Please download here in the "Downloads" tab: https://www.rosch-computer.de/prodDetail.jsp?pi=FL-EDC%201SE2%20Horizontal Thank you!

Last edited 4 years ago by softmove (previous) (diff)

comment:2 by Christian Franke, 4 years ago

Keywords: ssd added
Milestone: Release 7.2

Attribute set looks similar to existing entry InnoDisk iCF 9000 CompactFlash Cards.

comment:3 by Christian Franke, 4 years ago

Owner: set to Christian Franke
Status: newaccepted

comment:4 by Christian Franke, 4 years ago

Resolution: fixed
Status: acceptedclosed

comment:5 by softmove, 11 months ago

Hello,
I'm sorry to have to reopen this.
smartctl still shows the same output.
The only difference is that the SSD now shows as existing in the database.

Device is: In smartctl database 7.3/5319

Shouldn't things look different and the smart function work now?

The output still only works with

smartctl -xT very permissive

smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.0-18-amd64] (local build)

comment:6 by softmove, 11 months ago

Resolution: fixed
Status: closedreopened

comment:7 by Christian Franke, 11 months ago

Milestone: Release 7.2undecided

Please provide a new sample output.

comment:8 by softmove, 11 months ago

smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.0-18-amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     InnoDisk iCF 9000 / 1SE2 Cards
Device Model:     InnoDisk Corp. - EDC 1SE2 H 64GB
Firmware Version: 131216
User Capacity:    64.030.244.864 bytes [64,0 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database 7.3/5319
ATA Version is:   [No Information Found]
Local Time is:    Mon Feb 12 02:27:33 2024 CET
SMART support is: Ambiguous - ATA IDENTIFY DEVICE words 85-87 don't show if SMART is enabled.
                  Checking to be sure by trying SMART RETURN STATUS command.
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Disabled
Rd look-ahead is: Unavailable
Write cache is:   Disabled
DSN feature is:   Unavailable
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Disabled.
Total time to complete Offline 
data collection: 		(    0) seconds.
Offline data collection
capabilities: 			 (0x00) 	Offline data collection not supported.
SMART capabilities:            (0x0002)	Does not save SMART data before
					entering power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x00)	Error logging NOT supported.
					No General Purpose Logging support.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     ------   100   100   050    -    0
  5 Reallocated_Sector_Ct   -O----   100   100   050    -    0
 12 Power_Cycle_Count       ------   100   100   050    -    118
160 Uncorrectable_Error_Cnt ------   100   100   050    -    0
161 Valid_Spare_Block_Cnt   ------   100   100   050    -    591
162 Child_Pair_Count        ------   100   100   050    -    236
163 Initial_Bad_Block_Count ------   100   100   050    -    37
164 Total_Erase_Count       ------   100   100   050    -    7524477
165 Max_Erase_Count         ------   100   100   050    -    956
166 Min_Erase_Count         ------   100   100   050    -    890
167 Average_Erase_Count     ------   100   100   050    -    923
192 Power-Off_Retract_Count ------   100   100   050    -    0
194 Temperature_Celsius     ------   100   100   000    -    45 (Min/Max 36/66)
195 Hardware_ECC_Recovered  ------   100   100   050    -    0
196 Reallocated_Event_Count ------   100   100   050    -    0
198 Offline_Uncorrectable   ------   000   000   000    -    0
199 UDMA_CRC_Error_Count    ------   100   100   050    -    0
241 Host_Writes_32MiB       -O--CK   100   100   050    -    147273
242 Host_Reads_32MiB        -O--CK   100   100   050    -    299231
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

Read SMART Log Directory failed: scsi error badly formed scsi parameters

ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: scsi error badly formed scsi parameters
Read GP Log Directory failed

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

Read SMART Error Log failed: scsi error badly formed scsi parameters

SMART Extended Self-test Log (GP Log 0x07) not supported

Read SMART Self-test Log failed: scsi error badly formed scsi parameters

Selective Self-tests/Logging not supported

SCT Commands not supported

Device Statistics (GP/SMART Log 0x04) not supported

Pending Defects log (GP Log 0x0c) not supported

SATA Phy Event Counters (GP Log 0x11) not supported


comment:9 by softmove, 11 months ago

You can find detailed information about the implementation of the card's SMART commands in the link below starting on page 62: https://www.rosch-computer.de/file.jsp?aid=9806&sku=FL-EDC+1SE2+Horizontal

comment:10 by Christian Franke, 11 months ago

The new output is as expected. Unknown_Attribute is no longer printed.

The other commands fail because the device only supports a very limited subset of the ATA SMART Feature Set. This is obvious from the provided specification. For example, the important command SMART READ LOG is not mentioned. This needs to be fixed by the drive vendor.

This is unrelated to the drive database. See also the FAQ.

comment:11 by Christian Franke, 11 months ago

Milestone: undecidedRelease 7.2
Resolution: fixed
Status: reopenedclosed

r5110, r5111 work as expected, restoring ticket resolution.

comment:12 by softmove, 11 months ago

Ok, thank you for the information. I contacted the vendor.

Note: See TracTickets for help on using tickets.