Opened 5 years ago

Last modified 4 years ago

#1272 closed defect

Latest build isn't pulling full SMART data on hpsa devices — at Initial Version

Reported by: Dustin Marquess Owned by:
Priority: minor Milestone: Release 7.2
Component: all Version:
Keywords: cciss linux scsi Cc:

Description

NEW

$ sudo ./smartctl -x -d scsi+cciss,0 -r ioctl /dev/sg0 <
smartctl 7.1 2019-12-13 r5004 [x86_64-linux-4.18.13-geo1.ol6.x86_64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

START OF INFORMATION SECTION

Vendor: HP
Product: EG0900FBLSK
Revision: HPD8
Compliance: SPC-3

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

User Capacity: 900,185,481,216 bytes [900 GB]
Logical block size: 512 bytes

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Rotation Rate: 10000 rpm
Form Factor: 2.5 inches

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Logical Unit id: 0x5000c5004bc2745b

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Serial number: 6XS22P5S0000B235E1D7
Device type: disk
Transport protocol: SAS (SPL-3)
Local Time is: Fri Dec 20 14:21:58 2019 PST

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Temperature Warning: Enabled

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Read Cache is: Enabled
Writeback Cache is: Enabled

START OF READ SMART DATA SECTION

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

SMART Health Status: OK
Current Drive Temperature: 0 C
Drive Trip Temperature: 0 C

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Elements in grown defect list: 0

Error Counter logging not supported

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Device does not support Self Test logging
Device does not support Background scan results logging

NEW

OLD

smartctl 5.43 2016-09-28 r4347 [x86_64-linux-4.18.13-geo1.ol6.x86_64] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

/dev/sg0 [cciss_disk_00] [SCSI]: Device open changed type from 'sat,auto' to 'cciss'

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Vendor: HP
Product: EG0900FBLSK
Revision: HPD8

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

User Capacity: 900,185,481,216 bytes [900 GB]
Logical block size: 512 bytes

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Logical Unit id: 0x5000c5004bc2745b

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Serial number: 6XS22P5S0000B235E1D7
Device type: disk
Transport protocol: SAS
Local Time is: Fri Dec 20 14:25:23 2019 PST

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Device supports SMART and is Enabled
Temperature Warning Enabled

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

SMART Health Status: OK

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Current Drive Temperature: 21 C
Drive Trip Temperature: 65 C

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Manufactured in week 10 of year 2012
Specified cycle count over device lifetime: 10000
Accumulated start-stop cycles: 60
Specified load-unload count over device lifetime: 300000
Accumulated load-unload cycles: 1513

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Elements in grown defect list: 0

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Vendor (Seagate) cache information

Blocks sent to initiator = 773829256
Blocks received from initiator = 4244589878
Blocks read from cache and sent to initiator = 4231434536
Number of read and write commands whose size <= segment size = 3949760769
Number of read and write commands whose size > segment size = 39300
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Vendor (Seagate/Hitachi) factory information

number of hours powered up = 60047.63
number of minutes until next internal SMART test = 59

Vendor (Seagate/Hitachi) factory lpage: unknown parameter code [0x9]
Vendor (Seagate/Hitachi) factory lpage: unknown parameter code [0xe]

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Error counter log:

Errors Corrected by Total Correction Gigabytes Total

ECC rereads/ errors algorithm processed uncorrected

fast | delayed rewrites corrected invocations [109 bytes] errors

read: 0 0 0 782369620 0 4012475.671 0
write: 0 0 0 0 0 28874.763 0
verify: 0 0 0 3275645858 0 476.546 0

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Non-medium error count: 162

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

SMART Self-test log
Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ]

Description number (hours)

# 1 Background short Completed - 0 - [- - -]

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Long (extended) Self Test duration: 7250 seconds [120.8 minutes]

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Background scan results log

Status: scan is active

Accumulated power on time, hours:minutes 60047:38 [3602858 minutes]
Number of background scans performed: 2229, scan progress: 2.06%
Number of background medium scans performed: 2229

cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0
cciss_getlun(3, 0) = 0x0; scsi3addr: 00 00 00 c0 00 00 00 01
status=0

Protocol Specific port log page for SAS SSP
relative target port id = 1

generation code = 0
number of phys = 1
phy identifier = 0

attached device type: end device
attached reason: unknown
reason: hard reset
negotiated logical link rate: phy enabled; 6 Gbps
attached initiator port: ssp=1 stp=1 smp=1
attached target port: ssp=0 stp=0 smp=0
SAS address = 0x5000c5004bc27459
attached SAS address = 0x5001438010eef5e0
attached phy identifier = 0
Invalid DWORD count = 0
Running disparity error count = 0
Loss of DWORD synchronization = 18
Phy reset problem = 0
Phy event descriptors:

Invalid word count: 0
Running disparity error count: 0
Loss of dword synchronization count: 18
Phy reset problem count: 0

relative target port id = 2

generation code = 0
number of phys = 1
phy identifier = 1

attached device type: no device attached
attached reason: unknown
reason: unknown
negotiated logical link rate: phy enabled; 1.5 Gbps
attached initiator port: ssp=0 stp=0 smp=0
attached target port: ssp=0 stp=0 smp=0
SAS address = 0x5000c5004bc2745a
attached SAS address = 0x0
attached phy identifier = 0
Invalid DWORD count = 0
Running disparity error count = 0
Loss of DWORD synchronization = 0
Phy reset problem = 0
Phy event descriptors:

Invalid word count: 0
Running disparity error count: 0
Loss of dword synchronization count: 0
Phy reset problem count: 0

OLD

Change History (0)

Note: See TracTickets for help on using tickets.