Opened 6 years ago
Closed 6 years ago
#1195 closed defect (duplicate)
Incorrect time of self-test
Reported by: | Kovalkov Dmittrii | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | |
Component: | smartctl | Version: | |
Keywords: | Cc: |
Description
Hello!!!
Info:
root@1923 ~ # /opt/nobody/smartmontools-7.1/sbin/smartctl -a /dev/sda smartctl 7.1 2019-05-21 r4918 [x86_64-linux-2.6.32-5-amd64] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT Device Model: SAMSUNG HD753LJ Serial Number: S13UJ1MSB03195 LU WWN Device Id: 5 0024e9 0028a805c Firmware Version: 1AA01118 User Capacity: 750,156,374,016 bytes [750 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b Local Time is: Tue May 28 12:48:10 2019 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 9669) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 162) minutes. Conveyance self-test routine recommended polling time: ( 18) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 099 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 082 082 011 Pre-fail Always - 6210 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 9 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 12400 9 Power_On_Hours 0x0032 085 085 000 Old_age Always - 76614 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 9 13 Read_Soft_Error_Rate 0x000e 100 099 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 66 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 065 063 000 Old_age Always - 35 (Min/Max 20/37) 194 Temperature_Celsius 0x0022 064 061 000 Old_age Always - 36 (Min/Max 20/42) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 849825416 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 11077 - # 2 Extended offline Completed without error 00% 18418 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. root@1923 ~ #
Recent short self-test has 11077 value, but Power_On_hours 76614
I think, that 11077 = Power_On_hours - (65536 + 1) and it`s overflow in self-test lifetime
Please, help us
Note:
See TracTickets
for help on using tickets.
https://www.smartmontools.org/ticket/12
Note: this time stamp wraps after 216 hours, or 2730 days and 16 hours, or about 7.5 years.