Opened 6 years ago
Last modified 5 years ago
#1128 new enhancement
add to drivedb: Innodisk 3IE4 MLC 32GB DHS25-32GM41BW1DC-A90 — at Version 1
Reported by: | jeremy385892a | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | unscheduled |
Component: | drivedb | Version: | 6.6 |
Keywords: | ssd | Cc: |
Description (last modified by )
Could you add the following disk reference in the smartctl database ?
Here is the smartctl -a output:
>smartctl -a /dev/ada0 smartctl 6.3 2014-07-26 r3976 [NS-BSD 3.7.0- amd64] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: 2.5" SATA SSD 3IE4 Serial Number: B0021810230060001 LU WWN Device Id: 5 02b2a2 01d1c1b1a Firmware Version: L17606i User Capacity: 32,017,047,552 bytes [32,0 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-3 (unknown minor revision code: 0x011b) SATA Version is: SATA >3.1, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Tue Jan 3 01:46:44 2012 GMT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Total time to complete Offline data collection: ( 32) seconds. Offline data collection capabilities: (0x00) Offline data collection not supp orted. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x00) Error logging NOT supported. General Purpose Logging supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0000 000 000 000 Old_age Offline - 0 2 Throughput_Performance 0x0000 000 000 000 Old_age Offline - 0 5 Reallocated_Sector_Ct 0x0012 100 100 001 Old_age Always - 0 7 Unknown_SSD_Attribute 0x0000 000 000 000 Old_age Offline - 0 8 Unknown_SSD_Attribute 0x0000 000 000 000 Old_age Offline - 0 9 Power_On_Hours 0x0012 025 000 000 Old_age Always - 230 10 Unknown_SSD_Attribute 0x0000 000 000 000 Old_age Offline - 0 12 Power_Cycle_Count 0x0012 020 000 000 Old_age Always - 20 163 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 9 168 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 0 169 Unknown_Attribute 0x0000 100 000 000 Old_age Offline - 100 175 Program_Fail_Count_Chip 0x0000 000 000 000 Old_age Offline - 0 192 Power-Off_Retract_Count 0x0012 000 000 000 Old_age Always - 9 194 Temperature_Celsius 0x0002 055 100 000 Old_age Always - 55 (3 62 0 35 0) 197 Current_Pending_Sector 0x0000 000 000 000 Old_age Offline - 0 225 Unknown_SSD_Attribute 0x0000 000 000 000 Old_age Offline - 0 240 Unknown_SSD_Attribute 0x0000 000 000 000 Old_age Offline - 0 165 Unknown_Attribute 0x0012 043 100 000 Old_age Always - 43 167 Unknown_Attribute 0x0012 000 100 000 Old_age Always - 36 170 Unknown_Attribute 0x0013 100 100 010 Pre-fail Always - 142 171 Unknown_Attribute 0x0012 000 100 000 Old_age Always - 0 172 Unknown_Attribute 0x0012 000 100 000 Old_age Always - 0 176 Erase_Fail_Count_Chip 0x0000 000 000 000 Old_age Offline - 0 184 End-to-End_Error 0x0012 000 000 000 Old_age Always - 0 187 Reported_Uncorrect 0x0012 000 000 000 Old_age Always - 0 229 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 89569723955864 232 Available_Reservd_Space 0x0013 000 000 000 Pre-fail Always - 0 235 Unknown_Attribute 0x0002 000 000 000 Old_age Always - 0 241 Total_LBAs_Written 0x0002 100 100 000 Old_age Always - 35681 242 Total_LBAs_Read 0x0002 100 100 000 Old_age Always - 28410 SMART Error Log not supported SMART Self-test Log not supported Selective Self-tests/Logging not supported
Note:
See TracTickets
for help on using tickets.