not in smartctl database: HGST HDS5C4040ALE630
# smartctl -q noserial -x /dev/sda
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.17.10-1-ARCH] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: HGST HDS5C4040ALE630
Firmware Version: MPAOA580
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5700 rpm
Form Factor: 3.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Jul 28 13:35:23 2018 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unknown
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 28) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 731) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
2 Throughput_Performance P-S--- 100 100 054 - 0
3 Spin_Up_Time POS--- 135 135 024 - 575 (Average 458)
4 Start_Stop_Count -O--C- 100 100 000 - 10
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 100 100 020 - 0
9 Power_On_Hours -O--C- 100 100 000 - 10
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 8
192 Power-Off_Retract_Count -O--CK 100 100 000 - 10
193 Load_Cycle_Count -O--C- 100 100 000 - 10
194 Temperature_Celsius -O---- 166 166 000 - 36 (Min/Max 24/36)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL R/O 7 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x20 GPL R/O 1 Streaming performance log [OBS-8]
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 28/36 Celsius
Lifetime Min/Max Temperature: 24/36 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (91)
Index Estimated Time Temperature Celsius
92 2018-07-28 11:28 31 ************
... ..( 34 skipped). .. ************
127 2018-07-28 12:03 31 ************
0 2018-07-28 12:04 30 ***********
1 2018-07-28 12:05 30 ***********
2 2018-07-28 12:06 31 ************
3 2018-07-28 12:07 31 ************
4 2018-07-28 12:08 30 ***********
5 2018-07-28 12:09 30 ***********
6 2018-07-28 12:10 31 ************
7 2018-07-28 12:11 31 ************
8 2018-07-28 12:12 31 ************
9 2018-07-28 12:13 30 ***********
10 2018-07-28 12:14 31 ************
... ..( 53 skipped). .. ************
64 2018-07-28 13:08 31 ************
65 2018-07-28 13:09 ? -
66 2018-07-28 13:10 29 **********
67 2018-07-28 13:11 29 **********
68 2018-07-28 13:12 30 ***********
69 2018-07-28 13:13 30 ***********
70 2018-07-28 13:14 31 ************
71 2018-07-28 13:15 31 ************
72 2018-07-28 13:16 31 ************
73 2018-07-28 13:17 32 *************
74 2018-07-28 13:18 32 *************
75 2018-07-28 13:19 32 *************
76 2018-07-28 13:20 33 **************
77 2018-07-28 13:21 33 **************
78 2018-07-28 13:22 33 **************
79 2018-07-28 13:23 34 ***************
80 2018-07-28 13:24 34 ***************
81 2018-07-28 13:25 34 ***************
82 2018-07-28 13:26 35 ****************
... ..( 3 skipped). .. ****************
86 2018-07-28 13:30 35 ****************
87 2018-07-28 13:31 36 *****************
... ..( 3 skipped). .. *****************
91 2018-07-28 13:35 36 *****************
SMART WRITE LOG does not return COUNT and LBA_LOW register
SCT (Get) Error Recovery Control command failed
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 8 --- Lifetime Power-On Resets
0x01 0x018 6 0 --- Logical Sectors Written
0x01 0x020 6 0 --- Number of Write Commands
0x01 0x028 6 84354 --- Logical Sectors Read
0x01 0x030 6 1588 --- Number of Read Commands
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 9 --- Spindle Motor Power-on Hours
0x03 0x010 4 9 --- Head Flying Hours
0x03 0x018 4 10 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 0 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 36 --- Current Temperature
0x05 0x010 1 - N-- Average Short Term Temperature
0x05 0x018 1 - N-- Average Long Term Temperature
0x05 0x020 1 36 --- Highest Temperature
0x05 0x028 1 24 --- Lowest Temperature
0x05 0x030 1 - N-- Highest Average Short Term Temperature
0x05 0x038 1 - N-- Lowest Average Short Term Temperature
0x05 0x040 1 - N-- Highest Average Long Term Temperature
0x05 0x048 1 - N-- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 19 --- Number of Hardware Resets
0x06 0x010 4 18 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
Change History
(4)
Milestone: |
unscheduled → Release 7.2
|
Owner: |
set to Christian Franke
|
Status: |
new → accepted
|
Resolution: |
→ fixed
|
Status: |
accepted → closed
|
r5102, r5103.