Ticket #82: smartctl

File smartctl, 25.8 KB (added by virtuousfox, 14 years ago)

'smartctl -a' output

Line 
1running 'smartctl -a' for drive /dev/sda
2smartctl 5.39.1 2010-01-28 r3054 [x86_64-pc-linux-gnu] (local build)
3Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
4
5=== START OF INFORMATION SECTION ===
6Device Model: WDC WD15EARS-00Z5B1
7Serial Number: WD-WMAVU1578316
8Firmware Version: 80.00A80
9User Capacity: 1 500 301 910 016 bytes
10Device is: Not in smartctl database [for details use: -P showall]
11ATA Version is: 8
12ATA Standard is: Exact ATA specification draft version not indicated
13Local Time is: Wed Jun 30 21:43:24 2010 YEKST
14SMART support is: Available - device has SMART capability.
15SMART support is: Enabled
16
17=== START OF READ SMART DATA SECTION ===
18SMART overall-health self-assessment test result: PASSED
19
20General SMART Values:
21Offline data collection status: (0x84) Offline data collection activity
22 was suspended by an interrupting command from host.
23 Auto Offline Data Collection: Enabled.
24Self-test execution status: ( 0) The previous self-test routine completed
25 without error or no self-test has ever
26 been run.
27Total time to complete Offline
28data collection: (32400) seconds.
29Offline data collection
30capabilities: (0x7b) SMART execute Offline immediate.
31 Auto Offline data collection on/off support.
32 Suspend Offline collection upon new
33 command.
34 Offline surface scan supported.
35 Self-test supported.
36 Conveyance Self-test supported.
37 Selective Self-test supported.
38SMART capabilities: (0x0003) Saves SMART data before entering
39 power-saving mode.
40 Supports SMART auto save timer.
41Error logging capability: (0x01) Error logging supported.
42 General Purpose Logging supported.
43Short self-test routine
44recommended polling time: ( 2) minutes.
45Extended self-test routine
46recommended polling time: ( 255) minutes.
47Conveyance self-test routine
48recommended polling time: ( 5) minutes.
49SCT capabilities: (0x3031) SCT Status supported.
50 SCT Feature Control supported.
51 SCT Data Table supported.
52
53SMART Attributes Data Structure revision number: 16
54Vendor Specific SMART Attributes with Thresholds:
55ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
56 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
57 3 Spin_Up_Time 0x0027 191 178 021 Pre-fail Always - 5416
58 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 158
59 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
60 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
61 9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 2609
62 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
63 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
64 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 126
65192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 61
66193 Load_Cycle_Count 0x0032 166 166 000 Old_age Always - 104288
67194 Temperature_Celsius 0x0022 098 092 000 Old_age Always - 52
68196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
69197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
70198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
71199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
72200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
73
74SMART Error Log Version: 1
75No Errors Logged
76
77SMART Self-test log structure revision number 1
78Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
79# 1 Short offline Completed without error 00% 2599 -
80# 2 Short offline Completed without error 00% 101 -
81
82SMART Selective self-test log data structure revision number 1
83 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
84 1 0 0 Not_testing
85 2 0 0 Not_testing
86 3 0 0 Not_testing
87 4 0 0 Not_testing
88 5 0 0 Not_testing
89Selective self-test flags (0x0):
90 After scanning selected spans, do NOT read-scan remainder of disk.
91If Selective self-test is pending on power-up, resume after 0 minute delay.
92
93running 'smartctl -a' for drive /dev/sdb
94smartctl 5.39.1 2010-01-28 r3054 [x86_64-pc-linux-gnu] (local build)
95Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
96
97=== START OF INFORMATION SECTION ===
98Model Family: Western Digital Caviar Green family
99Device Model: WDC WD10EADS-00M2B0
100Serial Number: WD-WCAV51020987
101Firmware Version: 01.00A01
102User Capacity: 1 000 204 886 016 bytes
103Device is: In smartctl database [for details use: -P show]
104ATA Version is: 8
105ATA Standard is: Exact ATA specification draft version not indicated
106Local Time is: Wed Jun 30 21:43:24 2010 YEKST
107SMART support is: Available - device has SMART capability.
108SMART support is: Enabled
109
110=== START OF READ SMART DATA SECTION ===
111SMART overall-health self-assessment test result: PASSED
112
113General SMART Values:
114Offline data collection status: (0x82) Offline data collection activity
115 was completed without error.
116 Auto Offline Data Collection: Enabled.
117Self-test execution status: ( 0) The previous self-test routine completed
118 without error or no self-test has ever
119 been run.
120Total time to complete Offline
121data collection: (19560) seconds.
122Offline data collection
123capabilities: (0x7b) SMART execute Offline immediate.
124 Auto Offline data collection on/off support.
125 Suspend Offline collection upon new
126 command.
127 Offline surface scan supported.
128 Self-test supported.
129 Conveyance Self-test supported.
130 Selective Self-test supported.
131SMART capabilities: (0x0003) Saves SMART data before entering
132 power-saving mode.
133 Supports SMART auto save timer.
134Error logging capability: (0x01) Error logging supported.
135 General Purpose Logging supported.
136Short self-test routine
137recommended polling time: ( 2) minutes.
138Extended self-test routine
139recommended polling time: ( 226) minutes.
140Conveyance self-test routine
141recommended polling time: ( 5) minutes.
142SCT capabilities: (0x303f) SCT Status supported.
143 SCT Feature Control supported.
144 SCT Data Table supported.
145
146SMART Attributes Data Structure revision number: 16
147Vendor Specific SMART Attributes with Thresholds:
148ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
149 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
150 3 Spin_Up_Time 0x0027 118 102 021 Pre-fail Always - 7091
151 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 392
152 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
153 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
154 9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 6196
155 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
156 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
157 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 370
158192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 270
159193 Load_Cycle_Count 0x0032 182 182 000 Old_age Always - 54748
160194 Temperature_Celsius 0x0022 099 091 000 Old_age Always - 48
161196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
162197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 1
163198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 1
164199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
165200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
166
167SMART Error Log Version: 1
168No Errors Logged
169
170SMART Self-test log structure revision number 1
171Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
172# 1 Short offline Completed: read failure 90% 6186 1951323329
173# 2 Short offline Completed: read failure 90% 6181 1951323329
174
175SMART Selective self-test log data structure revision number 1
176 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
177 1 0 0 Not_testing
178 2 0 0 Not_testing
179 3 0 0 Not_testing
180 4 0 0 Not_testing
181 5 0 0 Not_testing
182Selective self-test flags (0x0):
183 After scanning selected spans, do NOT read-scan remainder of disk.
184If Selective self-test is pending on power-up, resume after 0 minute delay.
185
186running 'smartctl -a' for drive /dev/sdc
187smartctl 5.39.1 2010-01-28 r3054 [x86_64-pc-linux-gnu] (local build)
188Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
189
190=== START OF INFORMATION SECTION ===
191Model Family: Western Digital Caviar Green family
192Device Model: WDC WD10EADS-65L5B1
193Serial Number: WD-WCAU49389498
194Firmware Version: 01.01A01
195User Capacity: 1 000 204 886 016 bytes
196Device is: In smartctl database [for details use: -P show]
197ATA Version is: 8
198ATA Standard is: Exact ATA specification draft version not indicated
199Local Time is: Wed Jun 30 21:43:24 2010 YEKST
200SMART support is: Available - device has SMART capability.
201SMART support is: Enabled
202
203=== START OF READ SMART DATA SECTION ===
204SMART overall-health self-assessment test result: PASSED
205
206General SMART Values:
207Offline data collection status: (0x84) Offline data collection activity
208 was suspended by an interrupting command from host.
209 Auto Offline Data Collection: Enabled.
210Self-test execution status: ( 0) The previous self-test routine completed
211 without error or no self-test has ever
212 been run.
213Total time to complete Offline
214data collection: (22800) seconds.
215Offline data collection
216capabilities: (0x7b) SMART execute Offline immediate.
217 Auto Offline data collection on/off support.
218 Suspend Offline collection upon new
219 command.
220 Offline surface scan supported.
221 Self-test supported.
222 Conveyance Self-test supported.
223 Selective Self-test supported.
224SMART capabilities: (0x0003) Saves SMART data before entering
225 power-saving mode.
226 Supports SMART auto save timer.
227Error logging capability: (0x01) Error logging supported.
228 General Purpose Logging supported.
229Short self-test routine
230recommended polling time: ( 2) minutes.
231Extended self-test routine
232recommended polling time: ( 255) minutes.
233Conveyance self-test routine
234recommended polling time: ( 5) minutes.
235SCT capabilities: (0x303f) SCT Status supported.
236 SCT Feature Control supported.
237 SCT Data Table supported.
238
239SMART Attributes Data Structure revision number: 16
240Vendor Specific SMART Attributes with Thresholds:
241ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
242 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
243 3 Spin_Up_Time 0x0027 174 158 021 Pre-fail Always - 6300
244 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 273
245 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
246 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
247 9 Power_On_Hours 0x0032 088 088 000 Old_age Always - 8840
248 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
249 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
250 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 255
251192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 47
252193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 273
253194 Temperature_Celsius 0x0022 101 095 000 Old_age Always - 49
254196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
255197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 1
256198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 1
257199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
258200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
259
260SMART Error Log Version: 1
261No Errors Logged
262
263SMART Self-test log structure revision number 1
264Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
265# 1 Short offline Completed: read failure 90% 8830 113421466
266# 2 Short offline Completed: read failure 90% 8830 113421466
267# 3 Short offline Completed: read failure 90% 8824 113421466
268# 4 Short offline Completed without error 00% 0 -
269
270SMART Selective self-test log data structure revision number 1
271 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
272 1 0 0 Not_testing
273 2 0 0 Not_testing
274 3 0 0 Not_testing
275 4 0 0 Not_testing
276 5 0 0 Not_testing
277Selective self-test flags (0x0):
278 After scanning selected spans, do NOT read-scan remainder of disk.
279If Selective self-test is pending on power-up, resume after 0 minute delay.
280
281running 'smartctl -a' for drive /dev/sdd
282smartctl 5.39.1 2010-01-28 r3054 [x86_64-pc-linux-gnu] (local build)
283Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
284
285=== START OF INFORMATION SECTION ===
286Model Family: Western Digital Caviar SE Serial ATA family
287Device Model: WDC WD3000JS-00PDB0
288Serial Number: WD-WCAPD2588589
289Firmware Version: 21.00M21
290User Capacity: 300 067 970 560 bytes
291Device is: In smartctl database [for details use: -P show]
292ATA Version is: 7
293ATA Standard is: Exact ATA specification draft version not indicated
294Local Time is: Wed Jun 30 21:43:24 2010 YEKST
295SMART support is: Available - device has SMART capability.
296SMART support is: Enabled
297
298=== START OF READ SMART DATA SECTION ===
299SMART overall-health self-assessment test result: PASSED
300
301General SMART Values:
302Offline data collection status: (0x82) Offline data collection activity
303 was completed without error.
304 Auto Offline Data Collection: Enabled.
305Self-test execution status: ( 0) The previous self-test routine completed
306 without error or no self-test has ever
307 been run.
308Total time to complete Offline
309data collection: (9600) seconds.
310Offline data collection
311capabilities: (0x7b) SMART execute Offline immediate.
312 Auto Offline data collection on/off support.
313 Suspend Offline collection upon new
314 command.
315 Offline surface scan supported.
316 Self-test supported.
317 Conveyance Self-test supported.
318 Selective Self-test supported.
319SMART capabilities: (0x0003) Saves SMART data before entering
320 power-saving mode.
321 Supports SMART auto save timer.
322Error logging capability: (0x01) Error logging supported.
323 General Purpose Logging supported.
324Short self-test routine
325recommended polling time: ( 2) minutes.
326Extended self-test routine
327recommended polling time: ( 111) minutes.
328Conveyance self-test routine
329recommended polling time: ( 6) minutes.
330SCT capabilities: (0x103f) SCT Status supported.
331 SCT Feature Control supported.
332 SCT Data Table supported.
333
334SMART Attributes Data Structure revision number: 16
335Vendor Specific SMART Attributes with Thresholds:
336ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
337 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 10
338 3 Spin_Up_Time 0x0003 191 176 021 Pre-fail Always - 5450
339 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 701
340 5 Reallocated_Sector_Ct 0x0033 197 197 140 Pre-fail Always - 20
341 7 Seek_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0
342 9 Power_On_Hours 0x0032 063 063 000 Old_age Always - 27333
343 10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0
344 11 Calibration_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0
345 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 688
346194 Temperature_Celsius 0x0022 096 001 000 Old_age Always - 54
347196 Reallocated_Event_Count 0x0032 199 199 000 Old_age Always - 1
348197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
349198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0
350199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 479
351200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline - 0
352
353SMART Error Log Version: 1
354No Errors Logged
355
356SMART Self-test log structure revision number 1
357Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
358# 1 Short offline Completed without error 00% 27332 -
359# 2 Short offline Completed without error 00% 14339 -
360# 3 Extended offline Completed without error 00% 1082 -
361
362SMART Selective self-test log data structure revision number 1
363 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
364 1 0 0 Not_testing
365 2 0 0 Not_testing
366 3 0 0 Not_testing
367 4 0 0 Not_testing
368 5 0 0 Not_testing
369Selective self-test flags (0x0):
370 After scanning selected spans, do NOT read-scan remainder of disk.
371If Selective self-test is pending on power-up, resume after 0 minute delay.
372
373running 'smartctl -a' for drive /dev/sde
374smartctl 5.39.1 2010-01-28 r3054 [x86_64-pc-linux-gnu] (local build)
375Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
376
377=== START OF INFORMATION SECTION ===
378Model Family: Western Digital Caviar Blue Serial ATA family
379Device Model: WDC WD2500AAJS-00VTA0
380Serial Number: WD-WMART0626341
381Firmware Version: 01.01B01
382User Capacity: 250 058 268 160 bytes
383Device is: In smartctl database [for details use: -P show]
384ATA Version is: 8
385ATA Standard is: Exact ATA specification draft version not indicated
386Local Time is: Wed Jun 30 21:43:25 2010 YEKST
387SMART support is: Available - device has SMART capability.
388SMART support is: Enabled
389
390=== START OF READ SMART DATA SECTION ===
391SMART overall-health self-assessment test result: PASSED
392
393General SMART Values:
394Offline data collection status: (0x82) Offline data collection activity
395 was completed without error.
396 Auto Offline Data Collection: Enabled.
397Self-test execution status: ( 121) The previous self-test completed having
398 the read element of the test failed.
399Total time to complete Offline
400data collection: (4980) seconds.
401Offline data collection
402capabilities: (0x7b) SMART execute Offline immediate.
403 Auto Offline data collection on/off support.
404 Suspend Offline collection upon new
405 command.
406 Offline surface scan supported.
407 Self-test supported.
408 Conveyance Self-test supported.
409 Selective Self-test supported.
410SMART capabilities: (0x0003) Saves SMART data before entering
411 power-saving mode.
412 Supports SMART auto save timer.
413Error logging capability: (0x01) Error logging supported.
414 General Purpose Logging supported.
415Short self-test routine
416recommended polling time: ( 2) minutes.
417Extended self-test routine
418recommended polling time: ( 61) minutes.
419Conveyance self-test routine
420recommended polling time: ( 5) minutes.
421SCT capabilities: (0x303f) SCT Status supported.
422 SCT Feature Control supported.
423 SCT Data Table supported.
424
425SMART Attributes Data Structure revision number: 16
426Vendor Specific SMART Attributes with Thresholds:
427ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
428 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0
429 3 Spin_Up_Time 0x0003 175 174 021 Pre-fail Always - 2216
430 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 15
431 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
432 7 Seek_Error_Rate 0x000e 200 200 000 Old_age Always - 0
433 9 Power_On_Hours 0x0032 078 078 000 Old_age Always - 16500
434 10 Spin_Retry_Count 0x0012 100 253 000 Old_age Always - 0
435 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0
436 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 350
437192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 203
438193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 350
439194 Temperature_Celsius 0x0022 094 077 000 Old_age Always - 49
440196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
441197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 6
442198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 6
443199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
444200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 7
445
446SMART Error Log Version: 1
447No Errors Logged
448
449SMART Self-test log structure revision number 1
450Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
451# 1 Short offline Completed: read failure 90% 16499 22548153
452# 2 Extended offline Completed without error 00% 8303 -
453# 3 Short offline Completed without error 00% 4291 -
454
455SMART Selective self-test log data structure revision number 1
456 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
457 1 0 0 Not_testing
458 2 0 0 Not_testing
459 3 0 0 Not_testing
460 4 0 0 Not_testing
461 5 0 0 Not_testing
462Selective self-test flags (0x0):
463 After scanning selected spans, do NOT read-scan remainder of disk.
464If Selective self-test is pending on power-up, resume after 0 minute delay.